DeviceNet to PLCs or Devices

9

Multiple DN-3000s with Different PLC or Device Types


























RS-422/485 Multiple-Drop Networks


DeviceNet Host

PLC # 3
Brand I

PLC # 1
Brand M

PLC # 2
Brand I

PLC # 1
Brand I

PLC # 2
Brand O

PLC # 1
Brand O

PLC # 1
Brand S

DN-3000

# 5

DN-3000

# 4

DN-3000

# 3

PLC # 2
Brand A

DN-3000

# 2

PLC # 1
Brand A

DN-3000

# 1

2 3 2 3 2 3 2 3 2 3

NOTE:
1)
Each DN-3000 can support up to 32 PLCs/Devices (if they are network addressable internally).
2)
The DeviceNet Host can address a maximum of 63 DN-3000 units.
3)
Multiple Brands of PLCs or Devices may be addressed by the DeviceNet Host by using multiple

DN-3000s, but only one PLC/Device Protocol may be used on a single DN-3000 unit.

4) If multiple DN-3000s are to be used, each DN-3000 must be configured with a unique node

address (MAC ID) on the DeviceNet network.