Maaiinntteennaannccee

The Ikelite Housing should be given the same care and attention as

your other photographic equipment. In addition to normal

maintenance we recommend that the housing be returned to

Ikelite periodically to be checked and pressure tested.
1. D

Doo N

Noott leave the camera and housing in direct sunlight for

prolonged periods. Heat may damage the camera.

2. D

Doo N

Noott ship the camera in the housing.

3. Before using the housing, always check the tightness of the sseett

ssccrreew

w in each control knob.

Check each ccoonnttrrooll ggllaanndd penetrating the housing to make sure

they are tight. There is a slight chance that either could vibrate

loose during travel.

4. Keep the back and port o’ring clean and lightly lubricated. To

lubricate remove the o’ring from the back. Put a small amount

of lkelite lubricant on your fingers. Draw the o’ring through

your fingers to apply a light coating of lubricant. Only apply

enough lubricant to make the o’ring feel slick. D

Doo N

Noott ssttrreettcchh

tthhee oo’’rriinngg. This light coating of lubricant will help to keep the

o’ring from drying out and will help to show a dark sealing line

when the housing back is properly sealed.

5. Keep the area where the o’ring fits and the sealing surface clean.
6. Rinse the housing exterior thoroughly in fresh water after each

salt water use. Depress push buttons several times during rinse.

Dry with a soft cloth. Dry port to eliminate water spotting.

After several uses in salt water soak the housing in a mild soap

solution, rinse and dry.

CCAAU

UTTIIO

ON

N::

N

Neevveerr uussee sspprraayy lluubbrriiccaannttss aass tthhee pprrooppeellllaanntt

i

innggrreeddiieenntt ccaann ccaauussee tthhee ppllaassttiicc hhoouussiinngg ttoo ccrraacckk..

24

CCoonnttrrooll M

Maaiinntteennaannccee

Ikelite controls are designed to provide years of reliable service

with minimal maintenance.

1. Push button controls require no maintenance other than rinsing

in fresh water after saltwater use. If a push button control

becomes difficult to push or if it sticks when depressed, soak the

housing in luke warm fresh water. After a few minutes operate

the push button. If this does not correct the problem, return the

housing to Ikelite for maintenance.

2. Some of the controls have long shafts. These controls can be

pulled out, exposing the shaft (see drawing).

To lubricate the control, gently pull on the knob until the

stainless steel shaft is exposed. Lightly lubricate the shaft, then

move the shaft in and out several times. This will lubricate the

x’ring in the Ikelite control gland. This should be done before

using the housing after a prolonged storage period, or once a

week when the housing is in use.

housing

lubricate shaft

pull out to
expose shaft

22

LLeennss &

& PPoorrtt RReeccoom

mm

meennddaattiioonnss

C

Caannoonn LLeennsseess............................................................................................DDoom

mee................................FFllaatt PPoorrtt ................................FFllaatt PPoorrtt w

w//FFooccuuss

14mm EF 1:2.8 ..............................5503 (1)

15mm Fisheye ..............................5503.15

20mm ............................................5503

24mm ............................................5503

28mm ............................................5503 ............5501

35mm ............................................5503 ............5501

50mm Macro 1:2.8........................5503.50 ........5505

100mm Macro ..............................NR................5505.5

100mm EF Macro 1:2.8................NR................5505.58(4)

100mm USM Macro 1:2.8............NR................5505.45 ............5508.45

16-35mm USM ..............................5503.55(2)

17-35 Ultrasonic ............................5503.50 (2)

17-40mm USM..............................5503.50(2)

18-55 EF-S......................................5503

*20-35mm ......................................5503.50

*20-35 Ultrasonic ..........................5503 (2)

*22-55 Ultrasonic ..........................5503.50(2)

*24-85mm......................................5503.50

*28-70mm......................................5503.85 (3)

*28-80mm ....................................5503.50

*28-80mm USM............................5503.50(2)

28-105mm EF USM II ..................5503.55(2)

*28-105mm USM ..........................5503.80(2)

*35-80mm......................................5503 ............5502

*35-135mm ....................................5503.80

S

Siiggm

maa AAFF ((CCaannoonn)) ................................................DDoom

mee ....................FFllaatt PPoorrtt

*28-105mm f/2.8-4........................5503.80(2)
(*) Zoom lenses that do not focus to 12” require a +4 diopter close-up lens

be added to the lens when used underwater behind a dome port.

(1) Port shade may have to be removed to avoid vignetting.

(2) Lens requires special zoom clamps and focus sleeve #5509.28.

(3) Lens diameter does not allow zoom operation in the housing.

(4) Auto or Manual focus must be selected before closing the housing.

Requires special zoom clamp and focus sleeve #5509.28 for manual focus.

21

PPoorrttss CCoonnttiinnuueedd

FLAT PORT

For standard, macro, and telephoto lenses.

Due to refraction flat ports reduce the angle-of -coverage of a lens

and at the same time enlarge the image. This makes the flat port

ideal when using standard, macro or zoom lenses to shoot small

subjects. Note that if a port is long enough to accommodate the

full length of a 1:1 macro lens, the lens may vignette when used at

infinity. If access to the lens' full range is desired, then select a

dome port instead.

FLAT PORT

#5501. . . . . Lens up to 6.3cm (2.5")

#5502. . . . . Lens 6.3-8.9cm (2.5-3.5")

#5502.41 . . Lens 7.9-10.4cm (3.1-4.125")

#5505. . . . . Lens 8.9-11.4cm (3.5-4.5")

#5505.45 . . Lens 10.4-13cm (4.1-5.125")

#5505.5 . . . Lens 11.4-14cm (4.5-5.5")

#5505.58 . . Lens 13-15.5cm (5.1-6.125")

FLAT PORT WITH FOCUS

For long lenses whose focus collar extends beyond the housing

focus. Telephoto lenses longer than 135mm are not recommended.
#5506. . . Lens 8.9-11.4cm (3.5-4.5")

#5506.5 . Lens 11.4-14cm (4.5-5.5")

5507 . . . . Lens 14-16.5cm (5.5-6.5")

5508 . . . . Lens 16.5-19cm (6.5-7.5")

5508.05 . Nikor 105mm lens only