Multi–Platform Interface Feature Operation Guide

67

6400-LU0-DSC-Local Non-SNA 3174 Control Unit

LU0-DSC mode is utilized when host
controls are not needed to accomplish the
print function desired and the control unit is
attached by a VTAM-Controlled NON-SNA
Control Unit. An existing local 3174 NON-
SNA-connected control unit is assumed.
The steps required to install a local LU0-
DSC printer for host definitions are as
follows:

1.

Define to VTAM by adding logmode
entry to VTAM Logmode Table

2.

Define to JES2 (NOT required but
recommended. See details below)

3.

Define to CICS or another Application
Program such as VPS or JES328X
products.

4.

Select the options on the printer that
are appropriate for the environment.

Step 1 – VTAM Definition

The following should be added to the Local
Major Node VTAM definition.

LOC3174 VBUILD TYPE=LOCAL
LOCPU74 PU

CUADDR=nnn...

LOC64XX LU

LOCADDR=n,MODETAB=MYMODTB,DLOGMODE=64XXDSCL,
ISTATUS=ACTIVE

The following entry should be placed in the
VTAM MODE TABLE specified above or
another of your choice.

64XXDSCL MODEENT LOGMODE=64XXDSCL,
FMPROF=X'02',TSPROF=X'02',PRIPROT=X'60'
SECPROT=X'40',COMPROT=X'0000',RUSIZES=X'C7C7',
PSERVIC=X'000000000000185018507F00',
PSNDPAC=X'80',SRCVPAC=X'00',SSNDPAC=X'00'