EXAMPLE TWO

*AST798X*

Symbology Code 39

Desired Output: The input record must be Code 39 and be exactly
seven characters in length with the seventh character being an “X”. It
is divided into three fields; the first three characters, the next three
characters, and the last character. The output should reverse the order
of the first two fields, delete the last character, and add an F1 function
code at the end of each field. In addition, a time delay of 900 millisec-
onds should be added between the fields (after the F1) and another
delay of 2000 milliseconds added to the end of the record.

Formula

ID e LEN 07 07 M 07 X C 03 C 03 A <F1>
SEND BD DLY 09 AD DLY 20

Field List

Field A AST
Field B 798
Field C X
Field D <F1>

Keystroke Sequence
Prior to data editing, enable function codes in general selection
Enter Data Editing Setup

/E/D/FJ<ENTER>

Enter Data Editing and Enable

JA<ENTER>1<ENTER>

Enter Code ID and e (for Code 39) JC<ENTER>e<ENTER>
EnterLengthand 0707

JD<ENTER>0<ENTER>7<ENTER>0<
ENTER >7<ENTER>

Enter Match and 07X

JE<ENTER>0<ENTER>7<ENTER>X
<ENTER

Enter Count and 03

JF<ENTER>0<ENTER>3<ENTER>

Enter Count and 03

JF<ENTER>0<ENTER>3<ENTER>

Enter Add Field & <F1> character JJ<ENTER>\F1<ENTER>
Enter Field Sequence and BD

JK<ENTER>B<ENTER>D<ENTER>

Enter Add Delay and 09

JM<ENTER>0<ENTER>9<ENTER>

Enter B and C characters

BC<ENTER>

Enter Add Delay and 20

JM<ENTER>2<ENTER>0<ENTER>

Enter Exit Setup

JZ<ENTER>

Output Data

798<<F1>>.9s delay AST<<F1>>2s delay

4 4

4 5

EXAMPLE THREE

Track

MSR Track 1 data

Desired Output: Divide it up into seven fields so that the 1st field is the
first two characters, 2nd field is all characters from the first field to the
first “^” character, 3rd field is the first “^” character, 4th field is the
data between “^” marks, 5th field is the next “^” character, 6th field is
the next four characters, 7th field is the remaining characters. In
addition, an <ENTER> is inserted between fields in the data output
record. Only the 4th, 2nd, and 6th fields are outputted.

Formula

ID k C 02 S ^ S ^ C04 A<ENTER> SEND
DHBHFH

Field List

Field A

%B

Field B

0123774965

Field C

^

Field D

FISH/MARY

Field E

^

Field F

9612

Field G

4379F?

Field H

<ENTER>

Keystroke Sequence
Enter Data Editing Setup

/D/FJ<ENTER>

Enter Data Editing and Enable

JA<ENTER> 1<ENTER>

Enter Code ID and k (for MSR Track 1)

JC<ENTER> k<ENTER>

Enter Count and 02

JF<ENTER> 0<ENTER>
2<ENTER>

Enter Search String and the ^ character

JG<ENTER> ^<ENTER>

Enter Search String and the ^ character

JG<ENTER> ^<ENTER>

Enter Count and 04

JF<ENTER> 0<ENTER>
4<ENTER>

Enter Add Field & the <ENTER> character JJ<ENTER> ^N<ENTER>
Enter Field Sequence and DHBHFH

JK<ENTER> D<ENTER>
H<ENTER> B<ENTER>
H<ENTER> F<ENTER>
H<ENTER>

Enter Exit Setup

JZ<ENTER>

Output Data

FISH/MARY<ENTER>0123774965
<ENTER>9612<ENTER>