The appliance is designed to be

connected to 230 V monophase
electricity supply.

The connection must be carried out

in compliance with the laws and
regulations in force.

Before the appliance is connected:
1) check that the main fuse and the

domestic installation can support the
load (see the rating label);

2) check that the power supply is

properly earthed in compliance with the
current rules;

3) check the socket or the double

pole switch used for the electrical
connection can be easily reached with
the appliance built in the forniture unit.

The appliance is supplied with a

connection cable and the relevant plug.

The plug has to be fitted in a proper

socket.

If connecting the appliance directly to

the electric system, it is necessary that
you install a double pole switch between
the appliance and the electricity supply,
with a minimum gap of 3 mm. between
the switch contacts and of a type suitable
for the required load in compliance with
the current rules.

The connection cable has to be placed

in order that, in each part, it cannot reach
a temperature higher than 90°C.

The brown coloured phase cable

(fitted in the terminal block contact
marked with "L") must always be
connected to the network phase.