Remplacement of the voltage cable – IDEAL INDUSTRIES IZGS 68 ICTX User Manual

Page 16

Advertising
background image

16

Remplacement of the voltage
cable

The connection of the voltage cable

to the appliance's terminal block is of
type "Y". This means that its
replacement requires the specific
equipment of a technician. In this case,
only cable type H05V2V2-F T90 must
be used. The cable section must be
suitable to the voltage and the working
temperature. The yellow/green earth
wire must be approximately 2 cm longer
than the phase wires (Fig. 3-a).

To open the terminal block and

reach the terminals, proceed as
follows:

insert the point of a screwdriver into
the visible protrunding part of the
terminal block;

exert a light pressure and lift (Fig. 3-
b).

WARNING:

:

:

:

: The supply cable

replacement MUST only be
carried out by QUALIFIED
PERSONNEL
.

Fig. 3-b

Earth

(yellow/green))

Neutral

Fig. 3-a