2 software adjustment, 2 software adjustment (frequency) – Icom IC-GM1600E User Manual

Page 15

Advertising
background image

ADJUSTMENT

ADJUSTMENT CONDITION

MEASUREMENT

VALUE

UNIT

OPERATION

PLL LOCK
VOLTAGE

1 • Operating CH. : 16

• Receiving

PC

screen

Check the LVIN Data cell's
v a l u e i n t h e I / O c h e c k
window.
Click the "I/O check button"
o n t h e C S - M 9 0 / G M 1 6 0 0
A D J ' s s c r e e n ( s e e p a g e
5-3) to open the I/O check
window as below.

1.5–3.0 V [USA]

1.85–3.35 V [Others]

(Verify)

2 • Operating CH. : 16

• RF power : Low
• Transmitting

1.4–2.9 V

(Verify)

REFERENCE
FREQUENCY
[Ref. Freq.]

1 • Operating CH. : 16

• Connect the RF power meter or a 50

dummy load to the antenna connector.
• RF power : Low
• Transmitting

Top

Panel

Loosely couple the frequency
c o u n t e r t o t h e a n t e n n a
conector.

156.8000 MHz

±500 Hz

PLL LOCK VOLTAGE

NOTE: The above screen is an example.
Each transceiver has its own specific values.

5-2 SOFTWARE ADJUSTMENT (FREQUENCY)

Select the adjustment item with [

↑] / [↓] keys, then set the value with [←] / [→] keys on the connected PC.

5 - 4