5-2 SOFTWARE ADJUSTMENT (RECEIVING)

Select the adjustment item with [

↑] / [↓] keys, then set the value with [←] / [→] keys on the connected PC.

ADJUSTMENT

ADJUSTMENT CONDITION

MEASUREMENT

VALUE

UNIT

OPERATION

RECEIVE
SENSITIVITY
[BPF T1]
[BPF T2]
[BPF T3]
[BPF T4]

1 • Operating CH. : 16

• C o n n e c t t h e s t a n d a r d s i g n a l
generator to the antenna connector
and set as;
Frequency : 156.800 MHz
Level : +20 dB

µ*

Modulation : 1 kHz
Deviation : ±3.0 kHz
• Receiving

Top

pannel

Connect the distortion meter with an 8

load to the [MIC/SP] jack through the
JIG cable.

Minimum

distortion level

CONVENIENT:
RECEIVE SENSITIVITY can be adjusted automatically.
1. Put the cursor on the [BPF ALL Sweep] on the CS-M90/GM1600 ADJ's screen and push the [ENTER] key.
2. The connected PC tunes BPF T1−T4 to peak level automaticaly.
or
1. Put the cursor on the one of BPF T1−T4 as desired.
2. Push the [ENTER] key to start tuning.
3. Repeat 1 and 2 to perform additional BPF tuning.

SQUELCH
LEVEL
[Noise]

1 • Operating CH. : 16

• C o n n e c t t h e s t a n d a r d s i g n a l
generator to the antenna connector
and set as;
Frequency : 156.800 MHz
Level : –5 dB

µ* [USA]

–6 dB

µ* [Others]

Modulation : 1 kHz
Deviation : ±3.0 kHz
• Receiving

Top

panel

Push the [ENTER] key

on the keyboad

of the connected PC.

Automatic

adjustment

S-METER
[RSSI]

1 • Operating CH. : 16

• C o n n e c t t h e s t a n d a r d s i g n a l
generator to the antenna connector
and set as;
Frequency : 156.800 MHz
Level : –5 dB

µ* [USA]

–4 dB

µ* [Others]

Modulation : 1 kHz
Deviation : ±3.0 kHz
• Receiving

Top

panel

Push the [ENTER] key

on the keyboad

of the connected PC.

Automatic

adjustment

5 - 6

*The output level of the standard signal generator (SSG) is indicated as the SSG's open circuit.