Module test menu and hardware configuration report, Module, Test – IBM 6643 User Manual

Page 10: Menu, Hardware, Configuration, Report

Advertising
background image

If

NO,

continue

to

002 .

If

YES,

proceed

to

003 .

002

If

the

Power

Management

feature

is

enabled,

do

the

following:

1.

Start

the

Configuration/Setup

Utility

program

(see

“Setup

Utility

program”

on

page

5.)

2.

Select

Power

Management

from

the

Configuration/Setup

Utility

program

menu.

3.

Select

APM

.

4.

Be

sure

APM

BIOS

Mode

is

set

to

Disabled

.

If

it

is

not,

press

Left

Arrow

(})

or

Right

Arrow

(Æ)

to

change

the

setting.

5.

Select

Automatic

Hardware

Power

Management

.

6.

Set

Automatic

Hardware

Power

Management

to

Disabled

.

OR

7.

Go

to

“IBM

PC

Enhanced

Diagnostics”

on

page

6.

003

Run

the

IBM

PC

Enhanced

Diagnostics

test.

If

necessary,

refer

to

“Diagnostics

and

test

information”

on

page

5.

v

If

you

receive

an

error,

replace

the

part

that

the

diagnostic

program

calls

out

or

go

to

“IBM

PC

Enhanced

Diagnostics”

on

page

6.

v

If

the

test

stops

and

you

cannot

continue,

replace

the

last

device

tested.

v

If

the

LCD

display

has

problems

such

as

black

screen,

blinking

on-off,

or

the

screen

pallet

color

is

wrong,

go

to

“Display”

on

page

17.

Module

test

menu

and

hardware

configuration

report

Depending

on

the

diagnostics

version

level

you

are

using,

the

installed

devices

in

the

computer

are

verified

in

one

of

two

ways:

1.

At

the

start

of

the

diagnostic

tests,

the

Module

Test

Menu

is

displayed.

Normally,

all

installed

devices

in

the

computer

are

highlighted

on

the

menu.

2.

At

the

start

of

the

diagnostic

tests,

the

main

menu

appears.

From

this

menu,

select

System

Info

then

select

Hardware

Configuration

from

the

next

menu.

Normally,

all

installed

devices

in

the

computer

are

highlighted

on

this

report.

If

an

installed

device

is

not

recognized

by

the

diagnostics

program:

v

The

diagnostic

code

for

the

device

is

not

on

the

diagnostics

provided

with

that

device

v

The

missing

device

is

defective

or

it

requires

an

additional

diskette

or

service

manual.

v

An

unrecognizable

device

is

installed.

v

A

defective

device

is

causing

another

device

not

to

be

recognized.

v

The

SCSI

controller

failed

(on

the

system

board

or

SCSI

adapter).

v

Use

the

procedure

in

“Undetermined

problems”

on

page

56

to

find

the

problem.

If

a

device

is

missing

from

the

list,

replace

it.

If

this

does

not

correct

the

problem,

use

the

procedure

in

“Undetermined

problems”

on

page

56.

2

Hardware

Maintenance

Manual