Manual Setup

Normally, you can complete the setup procedure using

A

UTO

S

ETUP

; however,

if your screen image is still distorted after you perform

A

UTO

S

ETUP

or the

Installation CD does not run on your system, perform

M

ANUAL

S

ETUP

.

If the monitor is in standby

mode (STANDBY ON), it

might automatically turn off while

you are waiting for it to warm up.

1.

Have your monitor turned on for about 15 minutes, until the monitor
warms up.

2.

Display the image you most frequently use on the screen then go to

windows shut down mode.

3.

Press the OSD Enter button

at the bottom of the monitor to display

the initial OSD menu.

4.

Use the

or

button to select the Image Setup icon

and press

the OSD Enter button

to access.

5.

6.

You have completed monitor setup.

Use the or button to select Clock and Phase to adjustment.

(a) "Clock" (pixel frequency) controls the number of pixels scanned

by one horizontal sweep.

If the frequency is not correct, the screen shows vertical stripes

and the picture does not have the correct width.

(b) "Phase" adjust the phase of the pixel clock signal. With a wrong

phase adjustment the picture has horizontal disturbances in

light picture.

Use a select ( or ) button to manually adjust to correct and execute

save go to up menu then press the Exit ( ) button to leave OSD menu.