Inter-Tel 831.10507 User Manual

Page 13

Advertising
background image

13

CONSOLE DIAGRAM

USING THE CONSOLE

Refer to the console diagram above. The function of
each console control is explained below:

Temperature Display: During normal use, this dis-
play shows the actual water temperature. When the
Set Temp indicator is lit, the display will show the set
temperature.

Note: When problems occur, the temperature display
may show an error code. The error codes are
explained below:

HL

High temperature protection mode. If the water
temperature rises above 115°F (46°C), the
heater will shut off. If the temperature rises
above 122°F (50°C), the high temperature cir-
cuit will shut off the entire system. In either
case, once the water has cooled to normal, you
can press any button to reset the system.

FrE

Freeze protection mode. If the water tempera-
ture falls below 40°F (14°C), the pump will
begin cycling the water through the heater to
raise the temperature. This cycle will run for one
minute and may be repeated as needed.

FLC Flow related problems. You will need to call our

customer service department.

FLO Flow related problems. You will need to call our

customer service department.

PrH High temperature probe problem. You will need

to call our customer service department.

Prr

Temperature probe problem. You will need to
call our customer service department.

Pump Button: This button turns the pump on and off.
When the pump is running, the LED indicator above

the button will light. To turn the pump on high, press
the button once. The thera-jets will operate at full
speed. To turn the pump on low, press the button
again. The thera-jets will operate at low speed. After
you press the button a third time, the thera-jets will
shut off, unless it is time for the heat or filter cycles. If
you turn the pump off and it continues to operate,
check to see if the Heat On or Filter On indicator is lit
to see if either cycle is running.

Light Button: This button turns the light on and off.
When the light is on, the indicator above the light but-
ton will light. Note: The light will automatically turn off
after two hours.

Set Temp Indicator: This indicator will light when the
temperature is adjusted using the up and down buttons.
The thermostat can be set to heat the water from
70°F to 104°F (21°C to 40°C). While you are setting
the temperature, the temperature display will show the
temperature setting. The temperature setting will
remain in the display for five seconds after you
release the buttons. The Set Temp light will then turn
off and the display will show the actual water temper-
ature. The water heats at 1.5°F (2°C) per hour with
the cover on.

Filter On Indicator: This indicator lights when the
spa is running the filter cycle.

Note: To keep the heat and filter cycles from run-
ning, shut off the circuit breaker or the GFCI.

Heat On Indicator: This indicator lights when the spa
is running the heating cycle.

Air Control: The air control determines the amount of
air flowing through the spa jet system during operation.
If the control is turned to the left, the amount of air will
increase; if the control is turned to the right, the
amount of air will decrease.

Temperature

Display