Serial port 1 (cn7) and serial port 2 (cn8), Serial port uart, Rs-232 serial port (default) – IBM CMX58886CX User Manual

Page 42

Advertising
background image

34

CMX58886CX cpuModule

BDM-610000050

Rev A

Serial Port 1 (CN7) and Serial Port 2 (CN8)

Serial Port 1 (COM1) is implemented on connector CN7, and Serial Port 2 is implemented on connector CN8.
The serial ports are normally configured as PC compatible full-duplex RS-232 ports, but you may use the Setup
program to reconfigure these ports as half-duplex RS-422 or full-duplex RS-422 or RS-485. If you reconfigure the
ports, you must also select the I/O address and corresponding interrupt using Setup. Table 17 provides the
available I/O addresses and corresponding interrupts.

Serial Port UART

The serial ports are implemented with a 16550-compatible UART (Universal Asynchronous
Receiver/Transmitter). This UART is capable of baud rates up to 115.2 kbaud in 16450 and 16550A compatible
mode, and includes a 16-byte FIFO. Refer to any standard PC-AT hardware reference for the register map of the
UART. For more information about programming UARTs, refer to the Appendix.

RS-232 Serial Port (Default)

The default serial port mode is full-duplex RS-232. With this mode enabled, the serial port connectors must be
connected to RS-232 compatible devices. Table 18 provides the serial port connector pinout and shows how to
connect to an external DB-25 or DB-9 compatible serial connector.

Table 17

Serial Port Settings

I/O Address (hex)

IRQ

03F8

IRQ4

02F8

IRQ3

03E8

IRQ4

02E8

IRQ3

Table 18

Serial Port in RS-232 Mode

Pin

Signal

Function

In/Out

DB-25

DB-9

1

DCD

Data Carrier Detect

in

8

1

2

DSR

Data Set Ready

in

6

6

3

RXD

Receive Data

in

3

2

4

RTS

Request To Send

out

4

7

5

TXD

Transmit Data

out

2

3

6

CTS

Clear To Send

in

5

8

7

DTR

Data Terminal Ready

out

20

4

8

RI

Ring Indicate

in

22

9

9,10

GND

Signal Ground

7

5