0 thermal specifications, 1 case temperature and thermal design power, 2 case temperature metrology – Intel I/O Controller Hub 6300ESB User Manual
Page 9: Thermal specifications, Case temperature and thermal design power, Case temperature metrology, Intel
Thermal Specifications
Intel
®
6300ESB I/O Controller Hub Thermal and Mechanical Design Guide
9
3.0
Thermal Specifications
3.1
Case Temperature and Thermal Design Power
To ensure proper operation and reliability of the Intel 6300ESB ICH component, the case and
junction temperatures must be at or below the values specified in
. System and/or
component level thermal solutions are required to maintain the case temperature below the
maximum temperature specification while dissipating the thermal design power (TDP) listed in
.
3.2
Case Temperature Metrology
The component case temperature should be measured by attaching a thermocouple to the geometric
center of the package case top. Refer to
Appendix A, “Mechanical Drawings”
for package
dimensions.
Table 3. Intel
®
6300ESB I/O Controller Hub Thermal Specifications
Parameter
Maximum
Notes
T
case-nhs
105 °C
T
j-max
115 °C
TDP
3.9 W
NOTES:
1. T
case-nhs
is defined as the maximum package case temperature without a
thermal solution attached.
2. T
j-max
is defined as the maximum component temperature specification
measured at the hottest point in the processor die.