Thermal Specifications

Intel

®

6300ESB I/O Controller Hub Thermal and Mechanical Design Guide

9

3.0

Thermal Specifications

3.1

Case Temperature and Thermal Design Power

To ensure proper operation and reliability of the Intel 6300ESB ICH component, the case and
junction temperatures must be at or below the values specified in

Table 3

. System and/or

component level thermal solutions are required to maintain the case temperature below the
maximum temperature specification while dissipating the thermal design power (TDP) listed in

Table 3

.

3.2

Case Temperature Metrology

The component case temperature should be measured by attaching a thermocouple to the geometric
center of the package case top. Refer to

Appendix A, “Mechanical Drawings”

for package

dimensions.

Table 3. Intel

®

6300ESB I/O Controller Hub Thermal Specifications

Parameter

Maximum

Notes

T

case-nhs

105 °C

1

T

j-max

115 °C

2

TDP

3.9 W

NOTES:

1. T

case-nhs

is defined as the maximum package case temperature without a

thermal solution attached.

2. T

j-max

is defined as the maximum component temperature specification

measured at the hottest point in the processor die.

Advertising