Integra PLA-50V1 User Manual

Page 50

Advertising
background image

44

17. RED Gain Data

Function
The external control equipment changes the RED Gain Data of the plasma
monitor.

Transmission Data

DFH

80H

60H

7FH

04H

DATA00 to DATA03

CKS

DATA00: USER PICTURE Gain Flag

01H

DATA01: RED Gain Flag

01H

DATA02: RED Gain 1 (Bias)

D8H: -40

FFH: -1
00H: 0

IEH: +30

DATA03: RED Gain 2 (Drive)

D8H: -40

FFH: -1
00H: 0

IEH: +30

ACK

7FH

60H

80H

7FH

02H

DATA00 DATA01 CKS

DATA00: USER PICTURE Gain Flag

01H

DATA01: RED Gain Flag

01H

18. GREEN Gain Data

Function
The external control equipment changes the GREEN Gain Data of the plasma
monitor.
Transmission Data

DFH

80H

60H

7FH

04H

DATA00 to DATA03

CKS

DATA00: USER PICTURE Gain Flag

01H

DATA01: GREEN Gain Flag

02H

DATA02: GREEN Gain 1 (Bias)

D8H: -40

FFH: -1
00H: 0

IEH: +30

DATA03: GREEN Gain2 (Drive)

D8H: -40

FFH: -1
00H: 0

IEH: +30

ACK

7FH

60H

80H

7FH

02H

DATA00 DATA01 CKS

DATA00: USER PICTURE Gain Flag

01H

DATA01: GREEN Gain Flag

02H

19. BLUE Gain Data

Function
The external control equipment changes the BLUE Gain Data of the plasma
monitor.
Transmission Data

DFH

80H

60H

7FH

04H

DATA00 to DATA03

CKS

DATA00: USER PICTURE Gain Flag

01H

DATA01: BLUE Gain Flag

03H

DATA02: BLUE Gain1(Bias)

D8H:-40

FFH:-1
00H: 0

IEH: +30

DATA03: BLUE Gain2(Drive)

D8H: -40

FFH:-1
00H: 0

IEH:+30

ACK

7FH

60H

80H

7FH

02H

DATA00 DATA01 CKS

DATA00: USER PICTURE Gain Flag

01H

DATA01: BLUE Gain Flag

03H

Advertising