2 rs 485 interface, Version 2.00 – I-Data POLARIS Panel PC 19.1" User Manual

Page 28

Advertising
background image

User manual

POLARIS

Panel PC 19.1'' and Panel PC 15''

Version 2.00

Page 28 of 46

E_BMS790_POLARIS_PanelPC_19+15_Rev1.doc

User manual for POLARIS Panel PC 19.1" and 15"

Revision 1 / Status: January, 3

rd

, 2006

Technical data subject to change

6.2

RS 485 interface

BARTEC supplies all the RS 485 interfaces as RS 422.

Connection of a controller via an RS 485 interface of the POLARIS Panel PC.

RS485 Modul

Terminal compartment of the POLARIS Panel PC

Controller

PE

TxD A (TxD-)

RxD B (RxD+)

TxD B (TxD+)

TxD B (TxD+) / RxD B (RxD+)

TxD A (TxD-) / RxD A (RxD-)

RxD A (RxD-)

Data In

Data Out

Tx enable

17

18

See the interface description from the controller manufacturer for the relevant pin assignment of the controller.

If it is intended to use the RS422 as an RS485 interface, Pin 21/Pin 23 and Pin 22/Pin

must be bridged externally.

Pin 19-23, 20-24, 21-25, 22-26 are already connected inside.

In most cases, internal EMC measures allow the installation of termination resistors at
the beginning and the end of the bus line to be dispensed with.
Depending on local conditions, there might occasionally be impairments of data transfer.

to other POLARIS Panel PCs or
POLARIS Control

if final device