background image

Library Adapter Address

Specifies the LAN adapter address of the remote controller (the Library
Manager). This can be the Library Manager adapter card universally
administered address (UAA), such as 10005A8A5E75, or a locally
administered address (LAA), such as 40003494001A.

Library IP Address

The Library Manager IP Address is the unique internet address assigned to
the 3494 Library Manager.

Library Name

The Library Name is the Hostname defined in the TCP/IP network for the
Library Manager. In Figure 126 on page 198, libmgrc3.ibm.com is a
TCP/IP Hostname.

The following are the push-buttons:

OK

Close the information window.

Help

Display the help panel.

Operator Intervention

Certain conditions in the 3494, when detected, require short-term operator
intervention to resolve. These conditions do not stop the library manager from
accepting commands, but can delay the execution of certain queued operations.
Refer to “Chapter 7. Remote Library Manager Console Feature” on page 241 for
most conditions requiring intervention.

The library manager keeps track of the outstanding intervention-required conditions.
These conditions can be displayed on the library manager console and an operator
can indicate which conditions have been resolved. Steps are provided to resolve
each condition. For instructions on removing a cartridge from the gripper, see
“Cartridge Removal from the Gripper” on page 239.

The operator intervention window (see Figure 127 on page 200) displays the list of
conditions. If no outstanding conditions exist, the list is blank.

1. Determine what condition to resolve, perform the necessary action, and then

reply that the condition was resolved by highlighting the condition and choosing
OK. You can also choose the Help button for the operator actions.

Notes:

a. Certain conditions (for example, library full, Convenience Input⁄Output

Stationfull, and out of cleaner cartridges) are automatically cleared after you
resolve the intervention-required condition.

b. Certain conditions require the frame door to be opened to resolve.

c. You can highlight more than one condition. Choosing OK clears all the items

you highlighted.

2. Repeat step 1 until all needed conditions are resolved.

When you have replied that all outstanding conditions are resolved, the window
is closed. Also, you can close the window and resolve some conditions later by
choosing Cancel.