Burner and nozzle characteristics, K3g51s/hu – Indesit K3G51S/HU User Manual

Page 6

Advertising
background image

6

small but steady.
N.B.: in the case of liquid gas, the regulation screw
must be screwed in to the bottom.

check that the flame does not turn off when you turn
the tap quickly from high to low.

d Regulating the primary air of the burners:
The primary air of the burners requires no regulation.

Important
On completion of the operation, replace the old rating
sticker with one indicating the new type of gas used. This
sticker is available from our Service Centres.
Note
Should the pressure of the gas used be different (or vary)
from the recommended pressure, it is necessary to fit a
suitable pressure regulator onto the inlet pipe in
compliance with current National Regulations relative to
“regulators for channelled gas”.

Burner and nozzle characteristics

S S

R

A

K3G51S/HU

Table1 (For Hungary)

G 20

G 25.1

G 30

Burner

Diameter

(mm)

By-pass

1/100 (mm)

Thermal

power kW

Reduced

Nozzle

1/100

(mm)

Thermal

power kW

Nominal

Flow*

l/h

Nozzle

1/100

(mm)

Thermal

power kW

Flow*

l/h

Nozzle

1/100

(mm)

Thermal

power kW

Nominal

Flow*

g/h

Fast (R)

100

41

0.80

128

3,30

314

128

2,85

262

87

3,00

218

Semi Fast (S)

75

30

0.50

104

2,10

200

104

1,95

179

70

1,90

138

Auxiliary (A)

51

30

0,50

76

1,15

109

76

1,05

97

52

1,00

73

Supply pressures

Nominal (mbar)

Minimum (mbar)

Maximum (mbar)

25
20
30

25
20
30

30
20
35

* At 15°C and 1013 mbar-dry gas

P.C.S. G20 37,78 MJ/m

3

P.C.S. G25.1 39,11 MJ/m

3

P.C.S. G30 49,47 MJ/kg