Indesit IP 751 S C UK User Manual

Page 4

Advertising
background image

GB

4

use. If this is not the case, follow the instructions indicated

in the paragraph “Adapting to different types of gas.”

When using liquid gas from a cylinder, install a pressure

regulator which complies with current national regulations.
 Check that the pressure of the gas supply is consistent

with the values indicated in Table 1 (“Burner and nozzle

specifications”). This will ensure the safe operation and

longevity of your appliance while maintaining efficient

energy consumption.
Connection with a rigid pipe (copper or steel)
 Connection to the gas system must be carried out in

such a way as not to place any strain of any kind on the

appliance.

There is an adjustable L-shaped pipe fitting on the

appliance supply ramp and this is fitted with a seal in

order to prevent leaks. The seal must always be replaced

after rotating the pipe fitting (seal provided with

appliance). The gas supply pipe fitting is a threaded 1/2

gas cylindrical male attachment.
Connecting a flexible jointless stainless steel pipe to a

threaded attachment
The gas supply pipe fitting is a threaded 1/2 gas

cylindrical male attachment.

These pipes must be installed so that they are never

longer than 2000 mm when fully extended. Once

connection has been carried out, make sure that the

flexible metal pipe does not touch any moving parts and

is not compressed.
 Only use pipes and seals that comply with current

national regulations.
Checking the tightness of the connection
 When the installation process is complete, check the

pipe fittings for leaks using a soapy solution. Never use a

flame.
Adapting to different types of gas
To adapt the hob to a different type of gas other than

default type (indicated on the rating plate at the base of

the hob or on the packaging), the burner nozzles should

be replaced as follows:
1. Remove the hob grids and slide the burners off their

seats.

2. Unscrew the nozzles using a

7 mm socket spanner, and

replace them with nozzles for the

new type of gas (see table 1

“Burner and nozzle

characteristics”).

In the case of

the Mini WOK burner, use a

spanner with a 7 mm opening

to unscrew the nozzle (see figure).

3. Reassemble the parts following the above procedure in

the reverse order.

4. Once this procedure is finished, replace the old rating

sticker with one indicating the new type of gas used.

Sticker are available from any of our Service Centres.

• Adjusting the burners’ primary air :
Does not require adjusting.

• Setting the burners to minimum:
1. Turn the tap to the low flame position.
2. Remove the knob and adjust the adjustment screw,

which is positioned in or next to the tap pin, until the

flame is small but steady.

3. Having adjusted the flame to the required low setting,

while the burner is alight, quickly change the position of

the knob from minimum to maximum and vice versa

several times, checking that the flame does not go out.

4. Some appliances have a safety device (thermocouple)

fitted. If the device fails to work when the burners are

set to the low flame setting, increase this low flame

setting using the adjusting screw.

5. Once the adjustment has been made, replace the seals

on the by-passes using sealing wax or a similar

substance.

 If the appliance is connected to liquid gas, the regulation

screw must be fastened as tightly as possible.
 Once this procedure is finished, replace the old rating

sticker with one indicating the new type of gas used.

Stickers are available from any of our Service Centres.
 Should the gas pressure used be different (or vary

slightly) from the recommended pressure, a suitable

pressure regulator must be fitted to the inlet pipe (in order

to comply with current national regulations).

Advertising
This manual is related to the following products: