Burner and nozzle specifications – Indesit IP 751 S C UK User Manual

Page 5

Advertising
background image

GB

5

Burner and nozzle specifications

Table 1

Liquid Gas

Natural Gas

Burner

Diameter

(mm)

Thermal power

kW (p.c.s.*)

By-Pass

1/100

Nozzle

1/100

Flow*

g/h

Nozzle

1/100

Flow*

l/h

Nomin.

Ridot.

(mm)

(mm)

***

**

(mm)

Fast (R)

100

3,00

0,70

39

86

218

214

116

286

Reduced Fast
(RR)

100

2,60

0,70

39

80

189

186

110

248

Semi Fast (S)

75

1,65

0.40

28

64

120

118

96

157

Auxiliary (A)

55

1,00

0,40

28

50

73

71

79

95

Mini WOK (MW)

110

3,50

1,30

57

91

254

250

138

333

Supply
Pressures

Nominal (mbar)

Minimum (mbar)

Maximum (mbar)

28-30

20
35

37
25
45

20

17

25

*

At 15°C and 1013 mbar-dry gas

**

Propane

P.C.S. = 50.37 MJ/kg.

***

Butane

P.C.S. = 49.47 MJ/kg.

Natural

P.C.S. = 37.78 MJ/m

3

A

S

R

S

A

S

MW

S

A

MW

RR

S

S

IP 751 S C UK

IP 640 S UK

IP 641 S C UK

DATA PLATE

Electrical

connections

See data plate

This appliance conforms to the

following European Economic

Community directives:

-2006/95/EEC dated 12/12/06

(Low Voltage) and subsequent

amendments

- 89/336/EEC dated 03/05/89

(Electromagnetic Compatibility)

and subsequent amendments

- 93/68/EEC dated 22/07/93 and

subsequent amendments.

- 90/336/EEC dated 29/06/90

(Gas) and subsequent

amendments.

- 2002/96/EC