Frequency calibration, Approximate) – Icom IC-7700 User Manual

Page 184

Advertising
background image

13-5

Frequency calibration

(approximate)

A very accurate frequency counter is required to cali-
brate the frequency of the transceiver. However, a
rough check may be performed by receiving radio sta-
tion WWV, WWVH, or other standard frequency sig-
nals.

CAUTION: The IC-7700 has been thoroughly ad-
justed and tested at the factory before being
shipped. You should not have to re-calibrate it.

q

Push

to select USB mode.

w

Push and hold

for 1 sec. to clear the

PBT setting and make sure that the RIT/

TX func-

tion is not activated.

e

Set the frequency to the standard frequency station
minus 1 kHz.

• When receiving WWV or WWVH (at 15.00000 MHz) as

a standard frequency, set the operating frequency for
14.99900 MHz.

• Other standard frequencies can be used.

r

Push

several times to close a multi-func-

tion screen, if necessary.

• Calibration marker item

t

Push [F-7•SET] to select set mode menu screen.

y

Push [F-5•OTHERS] to enter Others set mode.

u

Push [F-1•

Y

] several times to select the “Calibra-

tion Marker” item.

i

Rotate the main dial clockwise to turn the calibra-
tion marker ON.

o

Push

once to return to set mode menu

screen.

!0

Push [F-2•ACC] to enter accessory set mode.

!1

Push [F-2•

Z

] several times to select the “REF Ad-

just” item.

!2

Rotate the main dial to adjust for a zero beat with
the received standard signal as shown at left.

• REF Adjust item

• Zero beat means that two signals are exactly the same

frequency, resulting in a single tone being emitted.

!3

Turn the calibration marker OFF in Others set
mode.

!4

Push

twice to exit set mode.

EXIT/SET

EXIT/SET

EXIT/SET

PBT-CLR

SSB

Main dial

F-2

F-1

ACC

F-5

OTHERS

EXIT/SET

F-7

SET

/

13

MAINTENANCE