Control Maintenance Cont.

3. Some of the controls have a short shaft and cannot be pulled

out exposing the shaft for lubrication. In the unlikely event
one of these controls sticks or becomes difficult to operate,
you can remove the control from the housing and lubricate it,
or return the housing to Ikelite for maintenance. To remove
the control (Diagram A), loosen the set screw in the knob
(allen wrench required); remove the knob. If there is salt or
dirt build-up on the exposed control shaft, clean the shaft.
Open the housing and gently slide the control shaft out of the
control gland. Clean and lightly lubricate the shaft, including
the end of the shaft. Slide the shaft back into the control
gland and gently slide it back and forth a few times without
fully removing the shaft from the gland. Replace the knob
noting the flat area on the shaft. The set screw in the knob
should tighten down against the flat area on the control, so
the knob does not turn on the shaft.

13

16

Loosen set screw

Tighten set screw down

against this flat area

when replacing the knob.

housing

gland

control

Lubricate end of shaft
before reinserting into
gland

Control Maintenance

Ikelite controls are designed to provide years of reliable service
with minimal maintenance.
1. Push button controls require no maintenance other than rinsing

in fresh water after saltwater use. If a push button control
becomes difficult to push or if it sticks when depressed, soak the
housing in luke warm fresh water. After a few minutes, operate
the push button. If this does not correct the problem, return the
housing to Ikelite for maintenance.

2. Some of the controls have long shafts. These controls can be

pulled out, exposing the shaft (see diagrams A and B on pages
16 & 17).
To lubricate the control, gently pull on the knob until the
stainless steel shaft is exposed. Lightly lubricate the shaft, then
move the shaft in and out several times. This will lubricate the
x-ring in the Ikelite control gland. This should be done before
using the housing after a prolonged storage period, or once a
week when the housing is in constant use.

15

14

Maintenance

The Ikelite Digital Housing should be given the same care and
attention as your other photographic equipment. In addition to
normal maintenance, we recommend that the housing be returned
to Ikelite periodically to be checked and pressure tested.
1. Do Not leave the camera and housing in direct sunlight for

prolonged periods. Heat may damage the camera.

2. Do Not ship the camera in the housing.
3. Before using the housing, always check the tightness of the set

screw in each control knob.
Check each control gland penetrating the housing to make sure
they are tight. There is a slight chance that either could vibrate
loose during travel.

4. Keep the back o-ring clean and lightly lubricated. To lubricate,

remove the o-ring from the back. Put a small amount of lkelite
lubricant on your fingers. Pull the o-ring through your fingers
to apply a light coating of lubricant. Only apply enough
lubricant to make the o-ring feel slick. Do Not stretch the
o-ring. This light coating of lubricant will help to keep the
o-ring from drying out and will help to show a dark sealing
line when the housing back is properly sealed.

5. Keep the area where the o-ring fits and the sealing surface of

the housing clean.

6. Rinse the housing exterior thoroughly in fresh water after each

salt water use. Dry with a soft cloth. Dry lens port to eliminate
water spotting.
After several uses in salt water, soak the housing exterior in a
mild soap solution, then rinse and dry before storing. When
storing the housing, remove the back o-ring, lightly lubricate,
and place in a plastic bag. Place the plastic bag with o-ring,
inside the housing for safe keeping.

7. If removing a housing push button, Do Not re-use the E-clip.

Contact Ikelite for replacement E-clips (part #0319.12).

Lubricants

1. Ikelite provides silicone lubricant with the housing. We recommend

you use only Ikelite lubricant on Ikelite products as some other
brands may cause the o-ring to swell and not seal properly.

2. Use only enough lubricant to lightly cover control shafts and

o-rings. Wipe off any excess lubricant with a clean cloth.
Lubricant is not a sealant, it is used to reduce friction. Excessive
lubricant can collect sand and dirt which may interfere with
proper sealing.

CAUTION

Never use spray lubricants as the propellant ingredient can
cause the plastic housing to crack.

Diagram A

Optional Accessories

Back o-ring

#0109

O-rings last for several years if properly maintained. (See
maintenance section). Always carry a spare o-ring in case the
original becomes damaged or lost.

Tray with Dual Release Handles

#9523.32

Dual Tray and Release Handles are required to mount two
external Substrobes (except AF35).

Macro Port Adaptor

#9306.82

Port adapter #9306.82 slides over the front of the lens port and
allows for the attachment of 67mm threaded macro lenses from
Inon and Epoque.

WD-4 Wide-Angle Conversion Dome

#6430.4

The removeable WD-4 corrects light

refraction underwater, restoring the
camera’s original 28mm angle of coverage.
Approximately 3/4 of the camera's zoom
range can be used with the dome in place.
Slight vignetting may occur at camera’s
widest angle setting. Additional
information is linked from the SX210 IS
web page at www.ikelite.com.

NOTE: Other Accessory and Wide-Angle Conversion lenses

cannot be used with this housing.

Complete information regarding these and other Ikelite products
including optional accessories, available at

www.ikelite.com

Advertising