Power Supply Specification
70
LOAD CAPACITY SPECIFICATIONS
The cross regulation defined as follows, the voltage regulation limits
DC include DC Output ripple & noise.
LOAD
+3.3V
+5V
+12V
-12V
+5VSB
Condition_1
X X X X 2A
Condition_2 0.5A
0.3A
1A
0A
0.1A
Condition_3 0.5A
2A
2A
0.8A
0.1A
Condition_4 1A
2A
17A
0.1A
0.1A
Condition_5
1A 10A 4A 0.1A 0.1A
Condition_6 4.5A
18A
12A
0.1A
0.1A
Condition_7 12A
2A
2A
0A
0.1A
Condition_8 17A
9.7A 10.5A
0.8A
2A
HOLD-UP TIME (@FULL LOAD)
115V / 60Hz : 17 mSec. Minimum.
230V / 50Hz : 17 mSec. Minimum.
OUTPUT RISE TIME
(10% TO 95% OF FINAL OUTPUT VALUE, @FULL LOAD)
+3.3Vdc
20ms Maximum
+ 5Vdc
20ms Maximum
+ 12Vdc
20ms Maximum
+ 5Vsb
20ms Maximum
115V-rms or 230V-rms
- 12Vdc
20ms Maximum
OVER VOLTAGE PROTECTION
Voltage Source
Protection Point
+3.3V
3.76V – 4.8V
+5V
5.6V – 7.0V
+12V
13.0V – 16.5V