Pos. function set screen (continued), Factory settings screen – JVC LWT0254-001B-H User Manual

Page 30

Advertising
background image

30

EN

Setting Up the Camera Using RM-P2580 (continued)

Use this screen to restore the values set in the menu to their factory settings.

POS. FUNCTION SET Screen (continued)

Item

Function/Set Value

Initial
Value

AVERAGE : PEAK

For setting the method of exposure detection according to the ratio between the average and
peak values.
●Larger AVERAGE Value : Use this setting when areas other than those highlighted are

dark and unclear. (Example: 10:0)

●Larger PEAK Value

: Use this setting when halation is seen to occur at the

highlighted areas on the screen. (Example: 5:5)

[Set values: 10:0, 9:1, 8:2, 7:3, 6:4, 5:5]

8:2

BLC MODE

For setting the backlight compensation function. Use this setting when an object appears dark
using the Auto Iris function due to the presence of a bright light source behind the object. Set in
such a way that unnecessary light sources are placed outside the photometry area.
OFF

: Do not perform backlight compensation.

AREA 1 to AREA 4 : Set according to the diagram below.

OFF

W. BALANCE

For setting the white balance adjustment feature. White balance can be adjusted for lighting
conditions within a color temperature range of 2,300 K to 10,000 K.
ATW

: Auto-Tracking White Balance mode. Adjusts the white balance automatically according

to the color temperature of the lighting. During

AATWB setting, the AR GAINB and AB

GAIN

B items are displayed as "- - -" and hue adjustment is not possible.

AWC : Switches to the Auto White Control mode and a message indicating

A<SET> AWC

EXEC

B will be displayed. Press the SET button to enable the AWC function for white

balance adjustment.

ATW

R GAIN

Adjusts the hue of R (red) when in the AWC mode.
Increase value to enhance the red color.
[Set values: 0 to 255]

^

B GAIN

Adjusts the hue of B (blue) when in the AWC mode.
Increase value to enhance the blue color.
[Set values: 0 to 255]

^

FACTORY SETTINGS Screen

Item

Function/Set Value

Initial
Value

CANCEL

Do not restore to factory settings. Press the MENU button or the SET button to return to the
menu screen.

^

CLEAR
(W/O POS. TITLE)

Restore factory settings. Upon pressing the SET button, a message indicating

AFACTORY

SETTINGS...

B will be displayed for approximately 20 seconds, upon which the set values will

be restored to their factory settings. Upon completion, a message indicating

ADATA

CLEARED

B will appear.

Preset positions as well as settings and titles for each position, however, will not be restored
to their initial values. Returns to the menu screen upon completion.

CLEAR (ALL)

Upon pressing the SET button, a message indicating

AFACTORY SETTINGS...B will be

displayed for approximately 20 seconds, upon which the set values will be restored to their
factory settings. Upon completion, a message indicating

ADATA CLEAREDB will appear.

All settings including the titles and preset positions will be restored to their initial values.
Returns to the menu screen upon completion.

Photometry

Area

Photometry Area

Photometry Area

Photometry

Photometry

OFF

AREA 1

AREA 2

AREA 3

AREA 4

Advertising