Cv-a33cl command list, Cv-a33cl – JAI CV-A33CL User Manual

Page 21

Advertising
background image

CV-A33CL

- 20 -

7.3. CV-A33CL command list

Command Name

Format

Parameter

Remarks

A – General settings and useful commands
EB

Echo Back

EB=[Param.]<CR><LF>

0=Echo off

1=Echo on

Off at power up

ST

Camera Status request

ST?<CR><LF>

Actual setting

HP

Online Help request

HP?<CR><LF>

Command list

VN

Firmware version

VN?<CR><LF>

3 letter version

ID

Camera ID request

ID?<CR><LF>

10 characters

MD

Model Name request

MD?<CR><LF>

≤ 10 characters

UD

User ID (Free text)

TR=[Param.]<CR><LF>

User can save and load free text

≤ 16 characters

B – Video Output

BA

Output bit allocation

BA=[Param.]<CR><LF>

0=10 bit

1=8 bit

Camera Link

C – Timing and shutter related commands
WS

Windows Scan

WS=[Param.]<CR><LF>

0=full frame

1=windows scan

WX

X Scan start coordinate

WX=[Param.]<CR><LF>

0-657

Start pixel #

WY

Y Scan start coordinate

WY=[Param.]<CR><LF>

0-490

Start line#

WW

X Scan size width

WW=[Param.]<CR><LF>

2-659

Window width

WH

Y Scan size height

WH=[Param.]<CR><LF>

3 – 493

Window height

AT

Auto Trigger

AT=[Param.]<CR><LF>

3-493

*)
Wind. 3H to 493H

TR

Trigger mode

TR=[Param.]<CR><LF>

0=normal
2=Pulse width

1=Edge pre-sel
3=Auto Trigger

SM

Shutter mode

SM=[Param.]<CR><LF>

0=Normal 1=Program.

exp

SH

Shutter speed

SH=[Param.]<CR><LF>

0=Off (1/120)
2=1/500
4=1/2000
6=1/10000

1=1/250
3=1/1000
5=1/5000

7=1/20000

All 8 steps are
valid in normal
trigger mode.

PE

Programmable expos.

PE=[Param.]<CR><LF>

2-493

Exp. 1H to 492H
H= 16.8µsec

D– Signals and polarity

LS

LVAL synchronous accum.

LS=[Param.]<CR><LF>

0= LVAL sync.

1=

LVAL a-sync.

*1) Only a-sync.

TI

Trigger Input

TI=[Param.]<CR><LF>

0= CamerLink

1= 12 pin Hiror

TP

Trigger polarity

TP=[Param.]<CR><LF>

0= active low

1= active high

*2)

E – Gain and analogue signals setting
BL

Black level

BL=[Param.]<CR><LF>

0-31

(0=low 31=high)

GA

Gain level

GA=[Param.]<CR><LF>

1-11

(0=low 11=high)

CB

Calibration of CMOS sensor CB=0<CR><LF>

0 is the only allowed parameter

Will calibrate the
CMOS sensor

F – Saving and loading data in EEPROM
LD

Load settings from camera
EEPROM

LD=[Param.]<CR><LF>

0=Factory data
2=User 2 area

1=User 1 area

Latest used data
default at power
up

SA

Save settings to camera

EEPROM

SA=[Param.]<CR><LF>

1=User 1 area

2=User 2 area

Parameter = 0 is
not allowed

*)

Auto trigger window will always start from top. Max frame rate with AT=3. It is 2 LVAL exposure + 9 LVAL offset.

*1)

The command LS is found on the first cameras. Only LS=1 is will work correct.

*2)

If positive logic is used (TP=1), the first trigger pulse after power up will be ignored. TTL only.

!!

Do not try to use commands not shown in this list.