External Control

Command outline

To control the monitor from external control equipment, send operation
commands to the monitor.

Example of communication procedures

1 Operation command to select “Input-3”.
2 Acknowledgment from the monitor.
3 The input is changed to “Input-3”.

Command structure

a:

Header

! : Operation command from the external control
device.
? : Enquiry command from the external control
device.
@ : Response from the monitor to an enquiry
command.
Ack (0x06): Positive acknowledge from the monitor.
Nak (0x15): Negative acknowledge from the
monitor.

b: Device ID

0x82 (fixed)

c:

Monitor ID

0x80 – 0xFF (Default setting is 0x80.)

d: Command

See “Command list” on the next page.

e:

Data

f:

Termination

Lf (0x0A)

1

2

3

! 0x82 0x80 IP 3 Lf

Ack 0x82 0x80 IP 3 Lf

GD-42X1

External control

equipment

! 0x82 0x80 IP 3 Lf

a

b

c

d

e

f