Input configurations, 10 input configurations, Sub connector plate w/ nl4 mpr inputs – JBL Professional JBL SR-X Speakers 981-00052-02 User Manual

Page 10: Way connector plate w/ nl4 mpr inputs, Way systems, Passive mode bi-amp mode

Advertising
background image

Input Configurations

Sub Connector Plate w/ NL4 MPR Inputs

SR4715/19X Discrete Mode

2-Way Connector Plate w/ NL4 MPR Inputs

In

Out

LF #2

LF #1

In

Out

LF #2

LF #1

± 2

± 2

± 1

± 1

In

Out

LF #2

LF #1

± 2

± 2

± 1

± 1

In

Out

LF

± 2

± 2

± 1

± 1

In

Out

LF

± 2

± 2

± 1

± 1

Passive Mode

Bi-Amp Mode

In

Out

In

Out

HF

LF

± 2

± 1

± 2

± 1

± 2

± 1

± 2

± 1

± 2

± 1

± 2

± 1

This section describes the different configurations of Input Connector Panel mode selections.
The wiring connections from the Input Panel to the transducers change when the mode selector is moved.
Please Note: Each line in the diagrams below represents a pair of wires. (E.g. both +1 and -1 connecting wires.)

10

Input Configurations

3-Way Systems

Passive Mode

Bi-Amp Mode

In

Out

HF

LF

In

Out

LF

± 2

± 1

± 2

± 1

± 2

± 1

± 2

± 1

MF

HF

MF

LPF

BPF

HPF

LPF

HPF

LPF = Low Pass Filter
BPF = Band Pass Filter
HPF = High Pass Filter

SR4718X Pin 1 Hot (as shipped)

SR4718X Pin 2 Hot *

SR4715/19X Pin 1 Hot (as shipped)

SRX4715/19X Pin 2 Hot *

LPF

HPF

* Units manufactured after April ‘00.

HF

LF

Advertising