Jackson Rack Conveyor Dishmachine User Manual

Page 3

Advertising
background image

5. Remove the motor support bracket.

6. With the motor support bracket removed, gently pull back on the
motor. You may have to move it from side to side, but it should start
to move back. Pull it completely away from the mounting studs on
the tub and set down gently to work on it.

7. Remove the gasket from the tub. If you are going to replace it
with a new one, do so at this time. Otherwise, carefully examine
the gasket for tears and other damage. If it is acceptable, set to the
side. If you are not going to replace the seal, go to step 16.

8. Using a large screwdriver (flathead preferred, but a phillipshead
will work just as well) and the 7/16” socket, loosen and then
remove the bolt holding the impeller to motor shaft. Refer to the
picture below.

9. With the bolt and washer removed, grasp the sides of the
impeller and pull up gently. The impeller should slide off of the
shaft. Remove the woodruff key as well and set to the side.

www.jacksonmsc.com

Rack Conveyor Motor Seal and Gasket Replacementt Instructions
Revision A (04/25/2005

3

Removing the rear clamp

Removing the motor support bracket

Removing the pump gasket

Removing the bolt that holds the impeller to the shaft

Removing the impeller

Removing the woodruff key

Advertising