RELAY 20067

Relay Location

Function of the 20067 relay

This relay once activated by the start-switch signal is design to
hold the current until the first cam of the timer hits the micro
switch on the timer. At that moment the signal on the relay is
disengaged and the timer takes over the start of the wash
cycle.

If this part fails, the
start switch must be
pressed and held for
15 seconds in order to
start the wash cycle.

13

TL- Power Switch
PS- Pressure Switch
SW2- Drain Switch

CR1 + CR2 - Micro Relay Switches

M1 + M2 + M3: Timer Cam Switches
TC- Start Switch
MP - Door Switch
TB - Thermostat
TV - Thermostat
CCB - Booster Contactor Contacts
ELB - Solenoid Coil

PD - Soap Pump

BR - Micro Relay coil

BCB - Booster Contactor coil
RV - Wash Tank Heater Element
RB - Booster Tank Heater Element
DP - Drain Pump
MT - Timer Motor
MPL - Wash Pump Motor
LL - Indicator Light - Power
LC - Indicator Light - Wash Cycle
LP - Indicator Light - Temperature Ready
CA - Capacitor - wash pump