Installation Instructions

OUCC002,00021CD

–19–18NOV06–1/4

Install NIR Sensor BZ100165

ZX1039596

–UN–10APR06

ZX1039597

–UN–10APR06

ZX1039598

–UN–26SEP06

A—NIR sensor—BZ100165
B—Shield—Z101939
C—Flange screws M8X16
D—Support Z101720
E—Flange screws M8X35
F—Flange nut
G—Sealing ring—Z101944
H—Support—AZ102820
I—Flange screws M8X25

1. Pre-assemble NIR sensor BZ100165 (A) with the

shield Z101939 (B) using 6 flange screws M8X16 (C).

2. Install support Z101720 (D) using 4 flange screws

M8X16 (C).

3. Place three screws M8X35 (E) and three flange nuts

(F) on sensor support as shown.

4. Insert sealing ring Z101944 (G) on glass adapter of

sensor BZ100165 (A).

IMPORTANT: To install the sealing ring (G) correctly,

align its centering protrusion with the
groove of glass adapter.

5. Install support AZ102820 (H) on spout using four

flange screws M8X25 (I) and flange nuts.