John Deere GREENSTAR BZ100157 User Manual

Page 12

Advertising
background image

Installation Instructions

OUCC002,00021CD

–19–18NOV06–2/4

ZX1039599

–UN–10APR06

ZX1040034

–UN–18NOV06

A—Sensor assembly
B—Support—AZ102820
C—Flange screws M8X25
D—Washers 8.4X24X2
E—Self-locking nuts
F—Wave length standard
G—Cover

6. Attach sensor assembly (A) to support AZ102820 (B)

using two flange screws M8X25 (C), two washers
8.4X24X2 (D) and two self-locking nuts (E) as shown.

IMPORTANT: To ease sensor assembly fold/unfold,

place washers (D) between support (B)
and sensor assembly brackets. Do not
overtighten self-locking nuts (E). Sensor
assembly (A) must remain easily
foldable.

The NIR sensor (A) is delivered with a dedicated wave
length standard (F). To avoid NIR sensor and non
dedicated wave length standard mix up, it is strongly
recommended to report the NIR sensor serial number
on its relevant wave length standard cover (G).

IMPORTANT: Prior to operating the NIR sensor (A),

carry out an initial wave length standard
measurement as described in Harvest
Monitor System Operator’s Manual.

If the wave length standard
measurement is not successful then a
black and white calibration of the NIR
sensor is required. Proceed as
described in the forage harvester
Technical Manual.

The wave length standard (F) must be kept in good
condition for future measurement. In this way, special
attention must be paid so that the wave length
standard (F) doesn’t come in contact with chemical
products such as:

Diesel

Gasoline (Leaded or unleaded)

Thinners

Engine cleaner

Cavity sealing

After cleaning

Finishing paint

Blackboard lacquer

Freeze protection

Z103757 (13DEC06)

10

Installation Instructions

011507

PN=12

Continued on next page