Connections – JVC TK-C675B User Manual

Page 8

Advertising
background image

8

Connections

When the system is composed of a single camera

When the system is composed of more than one camera

Controller*

Monitor

VIDEO OUT

CONTROL

PROTOCOL(1) SW4 :OFF
TERM : ON

24V AC

VIDEO
SWITCHER, etc.

CONTROLLER*

length of stub

length of stub

CONTROL Cable

CAM1

CAM2

CAM31

CAM32

PROTOCOL(1) : ON
MACHINE ID

: 01

TERM

: ON

PROTOCOL(1) : ON
MACHINE ID

: 02

TERM

: OFF

PROTOCOL(1) : ON
MACHINE ID

: 31

TERM

: OFF

PROTOCOL(1) : ON
MACHINE ID

: 32

TERM

: ON

length of stub

VIDEO
SWITCHER, etc.

CONTROLLER*

length of stub

CONTROL Cable

PROTOCOL(1) : ON
MACHINE ID

: 01

TERM

: ON

PROTOCOL(1) : ON
MACHINE ID

: 02

TERM

: OFF

PROTOCOL(1) : ON
MACHINE ID

: 32

TERM

: OFF

length of stub

CAM1

CAM2

CAM32

Terminate it
with 110ohm.

If this camera and the cables connected to this camera is used where there are strong electromagnetic waves or where there
is magnetism present, for example near a radio or TV transmitter, power transformer or an electric motor, the picture may
produce noise and the colors may be affected.
Optional controller is required to use the TK-C675B camera. Please contact your local dealer or installer for more information
about this controller.

CAUTION

Be sure to terminate the control signal cable at both ends. The cables (length of stub) connecting to non-terminated equipment
(camera or controller) must be as short as possible. If the length of stub is long, control may not be made correctly.

CAUTION

• Set the TERM switches of the cameras at both ends

(CAM1 and CAM32) to ON, and TERM switches of the
other cameras to OFF.

• Do not terminate at the controller.

• Set the TERM switch of CAM1 to ON, and also, terminate at the controller with 110 ohm.

Set the TERM switches of the other cameras to OFF.

When the controller is located at the end.

When the controller is not located at the end.

Advertising