How to use the ferrite core, Control signal connection, Connections (continued) – JVC TK-C675B User Manual

Page 9: Terminal board

Advertising
background image

9

Connections (continued)

control signal connection

Use a twisted-pair cable for the connection.

Duplex
When the camera is controlled with the full duplex proto-
col, set SW5 to OFF.

Simplex
When the camera is controlled with the simplex transmis-
sion protocol, set SW5 to ON.

Camera

Controller

RX+

RX–

TX+

TX–

TX+

TX–

RX+

RX–

Camera

Controller

RX+

RX–

TX+

TX–

Two wires must be connected.

AC 24V

AC 24V INPUT
terminals

Large ferrite core

Small ferrite core

Large ferrite core

TERMINAL BOARD

Control signal
terminals

VIDEO OUTPUT
terminals

Controller

Monitor, etc.

How to use the ferrite core

In order to reduce the generation of unnecessary signals, be sure to install the provided ferrite cores when connecting
the cables.

Install the ferrite cores within 100 mm of the camera-side connectors.
(Fasten the ferrite core with the provided wire clamp as the drawing
on the right.)

• For AC 24V INPUT terminals

Pass the AC 24V cable through the ferrite core twice and cconnect it to the camera.

• For Control signal terminals

Pass the Control signal cable through the ferrite core three times and cconnect it to the camera.

• For VIDEO OUTPUT terminals

Pass the VIDEO SIGNAL cable through the ferrite core and cconnect it to the camera.

Notes

Wire clamp

Four wires must be connected.

For example (connection with the RM-P2580)

Camera

RM-P2580

RX+ C

RX– D

C TX+

D TX–

TX+ A

TX– B

A RX+

B RX–

Advertising