Cv-a11 rs-232c command list, Cv-a11 – JAI CV-A11 User Manual

Page 19

Advertising
background image

CV-A11

7.2. CV-A11 RS-232C command list.

Command Name

Format

Parameter

Remarks

A – General settings and useful commands

EB Echo Back

EB=[Param.]<CR><LF> 0=Echo off

1=Echo on

Off at power up

ST Camera Status request ST?<CR><LF>

Actual setting

HP Online Help request HP?<CR><LF>

Command list

VN Firmware version

VN?<CR><LF>

3 letter version

B – Timing and shutter related commands
SC
Scanning format

SC=[Param.]<CR><LF> 0=full frame

2=1/3 partial

1=1/2 partial
3=1/6 partial

TR Trigger mode

TR=[Param.]<CR><LF> 0=normal

2=Pulse width
4=Long time

6=Smearless

1=Edge

3=Frame delay
5=Start/stop

SM Shutter mode

SM=[Param.]<CR><LF> 0=Normal 1=Programmab.

SH Shutter speed

SH=[Param.]<CR><LF> 0=1/30

2=1/60

4=1/250
6=1/1000

8=1/4000
10=1/20,000

12=1/60,000
14=1/100,000

1=1/50
3=1/125

5=1/500
7=1/2000

9=1/10,000
11=1/40,000

13=1/80,000

All15 step is valid
in normal trigger
mode.


In all trigger
modes shutter
speeds higher
than 9 will result
in 1/10,000

PE Programmable expos.

PE=[Param.]<CR><LF>

0=*1),

1=1.5H

1023=1023.5 H

H= 63.56µsec

HC HD accumulation

HC=[Param.]<CR><LF> 0=H synchron

accumulation

1=a-synchron
accumulation

a-sync. only for
TR=2 and TR=3

C – Signals and polarity
SO
Sync signal

SO=[Param.]<CR><LF> 0=no sync

1=sync on video

CW Clock/WEN

CW=[Param.]<CR><LF> 0= WEN out

1=Clock out

CW=0 if clock not
used

TP Trigger polarity

TP=[Param.]<CR><LF> 0= active low

1= active high

*2)

WP WEN polarity

WP=[Param.]<CR><LF> 0= active low

1= active high

D – Gain and analogue signals setting
AS
AGC Switch

AS=[Param.]<CR><LF> 0=AGC off

1=AGC on

0= manual gain

AG AGC Level

AG=[Param.]<CR><LF> 0=low 255=high

Range 0 to 255

GA Manual gain Level

GA=[Param.]<CR><LF> 0=low 255=high

Range 0 to 255

RP Rear Potentiometer

RP=[Param.]<CR><LF> 0=manual gain

1=rear potm.

SU Setup Level

SU=[Param.]<CR><LF> 0=low 255=high

Range 0 to 255

WC White clip Level

WC=[Param.]<CR><LF> 0=low 255=high

Range 0 to 255

GS Gamma Select

GS=[Param.]<CR><LF> 0=gamma 1

1=gamma 0.45

E – Saving and loading data in EEPROM
LD
Load settings from

camera EEPROM

LD=[Param.]<CR><LF> 0=Factory data

2=User 2 area

1=User 1 area

3=User 3 area

Latest used data
area becomes

default at next
power up

SA Save settings to

camera EEPROM

SA=[Param.]<CR><LF> 1=User 1 area

3=User 3 area

2=User 2 area


*1)

PE=0 has no function in triggered mode. PE=1 is 0.5H in continuous mode

*2)

If positive logic is used (TP=1), the first trigger pulse after power up will be ignored.

!!

Do not try to use commands not shown in the list.



- 18 -

Advertising