Appendix, Cv-a11 emulating cv-m10 interfacing, Wen out on pin 6 on 6 pin connector – JAI CV-A11 User Manual

Page 23: Cv-a11

Advertising
background image

CV-A11

10. Appendix

10.1. CV-A11 emulating CV-M10 interfacing


The CV-A11 has a slightly different pin configuration on the 12-pin Hirose connector, compared
to the M-series. This new configuration is compliant to the EIA-J standard. This means, however,
that the CV-A11 is not completely backward compatible with the CV-M10, CV-M40, etc in all
cases (depending on the cable configuration). The table below shows how to change the pin
configuration, by changing internal solder jumpers.

Please note: Only a qualified electronics technician or engineer should make these changes.

Hirose pin #

Function

JP2

JP3

JP5

JP1

JP4

Remarks

9

PCLK output enabled

Short

Note 2

9

No

connection

Open

10

WEN output

Open

Short

10

Connected to ground

Short

Open

11

Ext Trigger input

Open

Short

11

+12V DC in

Short

Open

Note 1: Configuration shown in Bold+Italic is factory default setting
Note 2: The RS-232C command “CW” must be set to CLK

Fig. 28. PK8304 Rear Board of CV-A11

10.2. WEN out on pin 6 on 6 pin connector

JP1 JP2

Instead of EEN output on pin #6 on the 6 pin Hirose
connector, WEN can be output by jumper settings. The 2
jumpers are found on the main board PK8298B, if the
bottom plate is removed.


Signal on pin #6

JP1

JP2

Remark

EEN out

Open Short default

WEN out

Short Open

Bold+Italic is factory default setting



Fig. 29. PK8298A main board.

- 22 -