Johnson Controls CP8C/CPLC*MP User Manual

Page 15

Advertising
background image

368262-UIM-B-1008

Johnson Controls Unitary Products

15

FIGURE 21: Thermostat Chart - Two Stage Air Conditioner with Single Stage Thermostat – Variable Speed or PSC Modulating Furnace

HM1

Humidistat

Y

Full Stage Compressor

G

Fan

*PP11C70224

THERMOSTAT

RH

24 – Volt Hot

(Heat XFMR)

RC

24 – Volt Hot
(Cool XFMR)

W

Full Stage Heat

Clipping Jumper W914 for

electric heat on thermostat

is not necessary

C

24 – Volt Common

R

24 – Volt Hot

Y1

Single

Stage Compressor

MODULATING

FURNACE CONTROL

G

Fan

MODULATING

FURNACE

Y/Y2

Second or Full

Stage Compressor

DHUM

Dehumidification-

Open on Humidity Rise

W

Modulating Heat

Part Numbers:

SAP = Legacy

1

1

Move HUMIDISTAT

jumper to “YES”

if humidistat is to be used.

ID MODELS

LO COMP

Single Stage

Compressor (OUT)

O

Reversing Valve

Energized in Cool

HI COMP

Second Stage

Compressor (OUT)

TWO STAGE

AIR

CONDITIONER

C

24 – Volt Common

R

24 – Volt Hot

Y1

First Stage Compressor

Y2

Second Stage

Compressor

External Humidistat

(Optional)

Open on Humidity Rise

2

Part Number:

S1-2HU16700124

2

TP(8,L)C

YP(8,L)C

CP(8,L)C

LP(8,L)C

Advertising
This manual is related to the following products: