10

Camera Control Terminals

Refer to the following table for connection cables. Carefully read the instruction manual supplied with the connected device.

Rear I/O Terminals

Camera control terminals

Signal code

Pin number

RX+

1

RX-

2

TX-

3

TX+

4

GND

5

NC

6

NC

7

NC

8

NC

9

(D-Sub 9 pin, male)

Terminal

Signal level

Remarks

[ALARM IN]

*Set the output impedance to 10k

or less.

Make Contact Input

[EMERGENCY]

[ALARM RESET]

*Set the output impedance to 10k

or less.

Make Contact Input

[EXT REC IN]

*Set the output impedance to 10k

or less.

Make Contact Input

[OPE ON/OFF]

*Set the output impedance to 10k

or less.

Make Contact Input

[REC TALLY]

[ALARM OUT]

[WARNING OUT]

[OPTION OUT 1, 2]

Open collector

(DC15V, 10mA or less)

250ms or more

250ms or more

Break

Make

250ms or more

250ms or more

1s or more

Approx. 50ms

Switches to off when

[OPERATE] is set at ON.

Switches to on when

[OPERATE] is set at OFF.

Make

External pull-up level

Individual output terminal and

COM terminal configure a

make contact. Individual output

terminals become “break” when

the VR-N900U is switched to

OFF.