Installation and Operation

English

Electrical Connections

Risk of electric shock. Connect only to a circuit

protected by a GFCI.

When using electrical products, basic precautions

should always be followed:

Always follow local building and electrical codes.

Grounding is required. The unit should be

installed and grounded by a qualified electrician.

Two separate GFCI protected circuits are required.
A separate, 120VAC, 15 Amp GFCI circuit is required for

the pump/motor.
If installing the optional heater, a separate and dedicated

120VAC, 15AMP, GFCI protected circuit is required.
If you are installing the optional heater, please refer to the

provided installation and operation manual that comes

packaged with the heater.

Reset

Test

X

X

For the pump/motor, install a 120 VAC, 15AMP,

GFCI duplex outlet to the stud wall underneath the

bathtub at 4˝ (101mm) above the floor. The duplex

outlet is not supplied.

Pump/motor

The duplex outlet must be mounted 4˝ (101mm)

above the floor line, or in accordance with local

building and electrical codes.

On the corner bathtubs, or 6060 bathtubs, a duplex

junction box has been provided. To access, remove

skirt access panel. See top views in Rough-In

section for location.

A separate GFCI protected outlet (not provided) is

required for pump/motor and is to be installed in the

junction box. The junction box is to be hard wired.

The motor is grounded to the junction box at the

factory.

Risk of component overheat. Do not use electric extension cord to power this unit.

Operating the motor/pump without enough water in the bathtub can cause leaking and permanent damage.

X

Y

Using a #8 solid copper wire, ground the pump

motor to the house electrical panel, or approved

local ground. A grounding lug is provided on the

pump motor

X

[

At initial start-up, and before each use thereafter

with power ON, push the GFCI test button. The

reset button should pop out.

Push this button in to reset. If the interrupter fails to operate in this manner, there is a ground current flowing or a

device malfunction, indicating the possibility of electrical shock.

Turn OFF power and do not use the bathtub until the source of the problem has been identified and corrected.

3-Prong Plug

Duplex Outlet

(Not Included)

3-Prong Plug

A heater comes standard on all Espree™ corner

bath models.

TM

Duplex Outlet

(Not Included)