English, Troubleshooting procedures, Espree™ bathtub series page 20 – Jacuzzi U961000 User Manual

Page 20: Installation and operation

Advertising
background image

Espree™ Bathtub Series

Page 20

www.jacuzzi.com

Installation and Operation

English

Troubleshooting Procedures

If the unit is within the warranty period, contact Jacuzzi Whirlpool Bath Service Support at 1-800-288-4002 with your bath’s serial number

before work is started. The serial number is located on the Specification/Serial Number Plate.

PROBLEM

PROBABLE CAUSES

REMEDY

Pump/motor does not start

Pump/motor shuts off by itself before time elapses

Pump/motor operates but not the multidirectional or

adjustable jets

Water leakage from pump unions

No power to pump/motor

Pump/motor not plugged in

Pump/motor faulty

Motor thermal protection has deactivated pump/motor

due to overheating (supply voltage low)

GFCI tripped

Inadequate supply wiring

Reset GFCI

Insert plug securely into outlet

Unsure that the tubing used to activate the pump/motor

is tightly secured to the bottom of the ON/OFF control

pad and to the AIR switch on back of the motor.

Contact Jacuzzi Luxury Bath @ 800-288-4002

Let motor cool; thermal protection will reset. Check for

proper ventilation (check supply voltage)

Reset GFCI. If it continues to trip, do not use this unit.

Disconnect the unit and have the problem corrected by

a licensed electrician before using.

Consult a licensed electrician to correct the wiring unit.

Jets are closed

Suction cover/strainer may be clogged

Open jets by rotating counter-clockwise

With the motor turned OFF, remove the suction cover/

strainer and remove any debris. Replace the suction

cover before operating

Overtightened, O-ring may be pinched or improperly

seated, undertightened

Loosen unions , check and reseat O-ring. If O-ring has

been pinched out of shape, replace (refer to number

below). When tightening union nuts, handtighten only.

Pump/motor operates but air is not injected into the

water

Air valves are closed

Open air control valves

Advertising