JVC TK-C1531EG User Manual

Page 16

Advertising
background image

16

Introduction

Q

[RX TERM-OFF,ON/INT,LL] Function Selector Switch

[RX TERM-OFF,ON] RX Signal Terminal ON/OFF Switch
This sets whether or not the signal between RX+

and RX-

from the

control signal connection terminals L should be terminated at the value of
110

K resistance.

ON

: Terminated at 110

K.

OFF

: Not terminated at 110

K.

If the system including the camera is the MULTIDROP (Multi DROP, RS-485)
system, only the last camera mounted along the control signal cable is set to

AONB and the other cameras are set to AOFFB. (In the case of the
MULTIDROP system, it is necessary to set the MACHINE ID.)
If the system including the camera is the P TO P (Point to Point, RS-422A)
system, set this switch of all the cameras to

AONB. To switch between

communication systems, use the item STYLE on the COMMUNICATION
screen. (

A Pg. 51)

(Default setting: ON)
[NT,LL] Selector Switch for Synchronizing System
This switch sets the synchronizing system for the camera.
INT

: This is set for internal synchronization (INT).

LL (Line Lock)

: This is set to synchronize the camera’s vertical

synchronization to the power frequency.
(Default setting: INT)

R

[POWER] Power indicator lamp

This lamp lights up when power is supplied to the camera.

S

Mounting Screw for Fall Prevention Wire

Use this screw when mounting the fall prevention wire to this unit. (Fall
prevention wire is not supplied with this product.)

Note:

● Connect the fall prevention wire to prevent this unit from falling accidentally.

T

AC 220 V

-240 V power cord

This connects the camera to a commercial AC 220 V

-240 V socket.

Name of Parts and their Functions (continued)

C

D

TK-C1530_EN.book Page 16 Friday, August 24, 2007 9:29 AM

Advertising
This manual is related to the following products: