Setup

Connecting alarm input/output terminal

Ⅵ Alarm input terminal

Connect infrared sensor, door sensor, metal sensor or sensor of manual
switch and the like.

● To prevent noise from entering the internal circuit, supply non-voltage

setting signal.

● Do not supply voltage.

● Can be set via menu whether to set to alarm when the contact is short

(MAKE), or when the contact is open (BREAK). (

A Pg. 39)

● Supply such that the alarm signal continues for more than 200 ms. The

recognition of alarm signal may not be guaranteed if less than 200 ms.

Ⅵ Alarm output terminal

Connect to alarm devices such as alarm, indicator, light or buzzer.

● Open-collector Low signal.

● Maximum voltage 25 V, current 30 mA.

Connecting the back panel (continued)

Z

CLASS 2 ONLY(U TYPE)
ISOLATED POWER ONLY(E TYPE)

SEE INSTRUCTION

MANUAL

POWER

VIDEO OUT

SELECTOR

SET

MENU

INT

LL

ON

RX TERM-OFF

+

1

2

DC12V d
AC24V H

IN

GND

Z Please use a shilded cable.

AUX

GND

22ǡ

TK-C1530_EN.book Page 24 Friday, August 24, 2007 9:29 AM