Alarm input signal

Connects to sensors such as infrared sensors,
door sensors, metal sensors and manual switches.

● To prevent noise from entering the internal

circuit, supply non-voltage contact signal to
the alarm input signal.

● Do not supply voltage.

● When the contact is short (MAKE) or open

(BREAK) on the menu, you can set it to
Alarm.

● Supply such that the alarm signal continues

for at least more than 500 ms. The alarm
signal may not be recognized if it is less than
500 ms.

Alarm output signal

Connect to alarm devices such as alarm, indicator,
light or buzzer.

● Alarm output signal is an open collector output

insulated with photo coupler.

● During an alarm, it is ON.

● As this terminal is polarized, be sure to

connect it such that the voltage of the + output
is higher than that of the - output.

● It will be damaged if reverse voltage is

supplied.

IN

COM

OUTPUT

COM

22

Rating:
Max. applied voltage : DC 20 V
Max. driving current

: 25 mA