Jøtul gf 200 dv ii lillehammer specifications, Gf 200 dv ii accessories, Input rates – Jotul GF 100 DV II User Manual

Page 5: Gf 200 dv ii miscellaneous kit contents

Advertising
background image

5

GF 100 DV II Nordic QT

GF 200 DV II Lillehammer

Jøtul GF 200 DV II Lillehammer
Specifications

GF 200 DV II Accessories

• Fuel Conversion Kit - NG ..................................................... 155627
• High Altitude Adjustment Kit - NG ................................ 155808
• High Altitude Adjustment Kit - LP ................................. 155809
• Blower Kit ................................................................................ 155631
• Antique Brick Kit ................................................................... 155815
• Wall Thermostat .................................................................... 750003
• Remote Control ...................................................................... 129706
• Mobile Home Floor Bracket Kit .... GF 200 DV II (6”) / 154923

............................................................. for Long Legs (8”) / 750304
....................................................................... for Plinth Kit / 154342

• Long Leg Kits ............................................. Matte Black / 154929

.......................................................................... Blue Black / 154930
..................................................................... Forest Green / 154931
.................................................................................. Ivory / 154932
............................................................................. Jøtul Iron / 155366

• Plinth Kits .................................................. Matte Black / 350081

.......................................................................... Blue Black / 350082
.................................................................................... Ivory / 350083
.................................................................. Forest Green / 350084
............................................................................. Jøtul Iron / 350085

Input Rates

Natural Gas

20,000 BTU/hr. maximum input
11,400 BTU/hr. minimum input

Propane

18,000 BTU/hr. maximum input
8,450 BTU/hr. minimum input

Inlet Pressure:

MIN

MAX

Natural Gas: 5.0 WC (1.24 kPa)

7.0 WC (1.74 kPa)

Propane: 12.0 WC (2.98 kPa) 14.6 WC (3.63 kPa)

Manifold Pressure:

MIN

MAX

Natural Gas: 1.2 WC (0.29 kPa)

3.8 WC (0.94 kPa)

Propane: 2.9 WC (0.72 kPa) 11.0 WC (2.74 kPa)

Piezo Ignitor / Standing Pilot
Weight: 180 lbs.

The Jøtul GF 200 DV II Lillihammer is a Direct

Vent gas heater designed as a sealed combustion, air
circulating gas appliance for residential applications.
This appliance is approved for installation using
6 5/8" X 4" vent pipe from the following manufacturers:

Simpson Dura-Vent GS
Security Vent, Ltd.
Amerivent Inc.
Selkirk Metalbestos

The Jøtul GF 200 DV II Lillehammer gas stove is

designed to burn NATURAL GAS or PROPANE only.
It is shipped from the factory equipped to burn
Natural Gas. If use with Propane is desired, the stove
must first be converted for use with that gas. Use
the LP Fuel Conversion Kit 155626 included with this
stove See page 14 for instructions.

GF 200 DV II Miscellaneous Kit Contents

• Fuel Conversion Kit - LP................................ 155626
• Rear Air Intake Restrictor Plate, Black -22111092

or Jøtul Iron - 22111085

• Side Air Intake Restrictor Plates, (2) .... 22099192

or Jøtul Iron - 22099185

* Decorative Wall Shield, Black ................ 22092692

or Jøtul Iron..... 22092692

18 ”

457 mm

21 1/8”

537 mm

As shipped

with 6”

(152 mm)

Legs

Height Dimensions with Optional Legs

Plinth Kit - subtract I” (25 mm)

Long Legs - add 2 1/4” (57 mm)

24 3/4”

630 mm

22 3/4”

560 mm

24 3/4”

630 mm

13”

330 mm

Leg To

Leg

18 1/2”

470 mm

17 1/4”

438 mm

Advertising