Specifications – Jackson 24 LT User Manual

Page 4

Advertising
background image

1

PERFORMANCE/CAPABILITIES

OPERATING CAPACITY (RACKS/HOUR)

RACKS PER HOUR

24

DISHES PER HOUR

600

GLASSES PER HOUR

600

OPERATING CYCLE (SECONDS)

WASH TIME

56

DRAIN TIME

29

RINSE TIME

35

TOTAL CYCLE TIME

120

TOTAL WATER CONSUMPTION

GALLONS PER HOUR (80% CAP.)

28.8

GALLONS PER RACK

1.2

TEMPERATURES

WASH ---°F (MINIMUM)

120

WASH ---°F (RECOMMENDED)

140

RINSE ---°F (MINIMUM)

120

RINSE ---°F (RECOMMENDED)

140

ELECTRICAL REQUIREMENTS

WASH PUMP MOTOR HORSEPOWER

3/4

NOTE: Typical Electrical Circuit is based upon (1) 125% of the
full amperage load of the machine and (2) typical fixed-trip
circuit breaker sizes as listed in the NEC 2002 Edition. Local
codes may require more stringent protection than what is
displayed here. Always verify with your electrical service
contractor that your circuit protection is adequate and meets
all applicable national and local codes. These numbers are
provided in this manual simply for reference and may change
without notice at any given time.

RINSE

TYPICAL

HEATER

TOTAL ELECTRICAL

VOLTS PH

HZ

RATINGS

AMPS

CIRCUIT

115 1 60

N/A

10

15 AMP

WATER REQUIREMENTS

INLET TEMPERATURE (RECOMMENDED)

140°F

INLET TEMPERATURE (MINIMUM)

120°F

GALLONS PER HOUR

28.8

WATER LINE SIZE NPT (MINIMUM)

1/2”

DRAIN LINE SIZE NPT (MINIMUM)

1 3/8”

FLOW PRESSURE P.S.I.

20A5

MINIMUM CHLORINE REQUIRED (PPM)

50

FRAME DIMENSIONS

WIDTH

24 1/4”

DEPTH

22 5/8”

HEIGHT

33 1/4”

NOTE: Always refer to the machine data plate for specific
electrical and water requirements. The material provided on
this page is for reference only and may be subject to change
without notice.