Installation

Technical specifications

Dimensions

Width

44.6 cm

Height

81.8 - 87.8 cm

Max depth

55.5 cm

Max depth with open door

114 cm

Electrical connection:

Information on the electrical connection is given on the rating plate on the inner

Voltage

edge of the dishwasher’s door.

Overall power
Fuse

Water supply pressure

Minimum

0,05 MPa (0,5 bar)

Maximum

0,8 MPa (8 bar)

Capacity

9 place settings

Electrical connection

Any electrical work required to install this appliance should be
carried out by a qualified electrician or competent person.

WARNING:THIS APPLIANCE MUST BE
EARTHED.

The manufacturer declines any liability should this
safety measure not be observed.

Before switching on, make sure the electricity supply voltage is the
same as that indicated on the appliance’s rating plate.The rating
plate is located on the side of the dishwasher’s door.

The plug moulded onto the lead incorporates a 13amp BSI362
fuse. Only ASTA or BSI fuses should be used.

To isolate the dishwasher from mains, remove the mains plug.

If the plug that is fitted to your appliance is not suitable for the
socket, it must be cut off and the appropriate plug fitted.

Important
The wires on the mains lead are coloured in accordance with the
following code:

Green and Yellow

- Earth

Blue

- Neutral

Brown

- Live

If you fit your own plug, the colours of the wires in the mains lead
of your appliance may not correspond with the markings
identifying the terminals in your plug.

Proceed as follows:
1.
Connect the Green and Yellow (earth) wire to the terminal

in the plug which is marked with the letter "E" or the earth
symbol

or coloured green and yellow.

2. Connect the Blue (neutral) wire to the terminal in the plug

which is marked with the letter "N" or coloured black.

3. Connect the Brown (live) wire to the terminal in the plug

which is marked with the letter "L" or coloured red.

4. Upon completion there must be no cut, or stray strands of

wire present and the cord clamp must be secure over the
outer sheath.

The plug must not be used if the fuse cover/carrier is lost.The
cover/carrier is indicated by the coloured insert at the base of
the plug.

A replacement cover/carrier must be obtained from your local
Service Force centre. Please contact our extended warranty
administrators on 0870 0107887 who will give you details for
your local Service Force centre.