External Control

7 About the external control

This monitor has three external control terminals.

MAKE/TRIGGER terminal (RJ-45): The following external control systems are available.

(1) MAKE (make contact) system: Controls the monitor by short-circuiting the corresponding pin terminal to

the GND pin terminal, or disconnecting (opening) it.

(2) TRIGGER (trigger) system: Controls the monitor by sending the pulse signal instantaneously to the

corresponding pin terminal.

☞ “Using the MAKE/TRIGGER system” on the right
RS-485 terminals (RJ-45): Controls the monitor with the RS-485 system. (

☞ “Using the serial communication”

on page 22)

RS-232C terminal (D-sub 9-pin): Controls the monitor with the RS-232C system. (

☞ “Using the serial

communication” on page 22)

Set the following items of “REMOTE SETTING” in SET-UP MENU according to the external control terminal and
control system. (

☞ “SERIAL TYPE,” “PARALLEL TYPE” on page 18)

Control terminal

Control system

The settings of this unit

“SERIAL TYPE” setting

“PARALLEL TYPE”
setting

MAKE/TRIGGER
terminal

MAKE

MAKE

TRIGGER

TRIGGER

RS-485 terminal

Serial
communication

RS-485

RS485*

1

RS-232C terminal

RS-232C

RS232C*

1

*

1

For a monitor connected to a personal computer etc, select the terminal the equipment is actually connected to.

For other monitors, select “RS485.”

Control priority is as follows.
MAKE > TRIGGER = serial communication = buttons and menu on the monitor

• You can use external control even when “CONTROL LOCK” is set to “VOL.LOCK” or “ALL LOCK” (

☞ page 19).

• When the monitor is off (on standby), external control is not available. But certain external controls (starting/

terminating communication, turning on the monitor) are available through the serial communication (

☞ page 23).

<MAKE/TRIGGER system>
You can control the monitor by a personal computer or dedicated controller*

2

.

• “Using the MAKE/TRIGGER system” on the right.

*

2

The controller is not commercially available. Consult your dealer if you need it.

<Serial communication>

• For the details, see page 22.

PC, etc.

RS-485 IN

or

RS-232C

RS-485

OUT

RS-485

IN

RS-485

OUT

RS-485

IN

RS-485

OUT

7 Using the MAKE/TRIGGER system

The MAKE/TRIGGER terminal is configured as follows. You can assign a function to each pin terminal in
“REMOTE SETTING.” (

☞ “PIN1, PIN2, PIN3, PIN4, PIN5” in “PARALLEL TYPE” on page 18)

• You cannot change the functions assigned to the pin terminals from 6th to 8th.

Pin No.

Pin name

1

PIN1

2

PIN2

3

PIN3

4

PIN4

5

PIN5

6

TALLY*

1

7

ENABLE*

2

8

GND

*

1

The 6th pin terminal controls turning on or off the tally lamp (available to control even when the 7th pin terminal

is invalid).

*

2

The 7th pin terminal makes the external control valid/invalid. Make sure to control the terminal by the MAKE

system.

To assign the functions to the pin terminals

For the operation procedure, see page 7.

1

Select “REMOTE SETTING” on the SET-UP MENU.

2

Set

“PARALLEL

TYPE”

to

“SET.”

3

Select a pin name (“PIN1” – “PIN5”) for which you want to assign a function, then select the function you want

to assign.
• For the selectable functions, see the table on page 21.

Operation of the external control

1

Set “PARALLEL TYPE” of “REMOTE SETTING” to “MAKE” or “TRIGGER” in the SET-UP MENU.

2

Short-circuit the 7th pin terminal (ENABLE) to the 8th pin terminal (GND) so that the monitor can be controlled

by the external control.

3

When the “MAKE” system is selected: Operate each function by short-circuiting the corresponding pin terminal

to the 8th pin terminal (GND) or opening it.
When the “TRIGGER” system is selected: Operate each function by pulse control, that is short-circuiting the
corresponding pin terminal to the 8th pin terminal (GND) for about 1 second and opening it.

• When changing the input with MAKE system, only one pin terminal must be short-circuited. (Other pin terminals