Installation, 15 connections to camera terminal board – JVC TK-C553 User Manual

Page 15

Advertising
background image

15

Connections to Camera Terminal Board

INSTALLATION

Connections to Terminal Board
Remove the terminal board cover and con-
nect the video signal cable (coaxial cable)
(

× 1).

Connect the DC 12 V or AC 24 V power cables
(

× 2).

In a system where the Remote Control Unit
(RM-P2580), etc. is used, connect the con-
trol signal cables (

× 4).

DC 12 V or AC 24 V power supply cable
Connect the DC 12 V or the AC 24 V power
supply to the DC 12V/AC 24V terminals on
the terminal board. To prevent connection
errors or a cable disconnection, we recom-
mend the use of lug plates for the connec-
tions.
The following table shows the connection dis-
tances and connection cables provided that
2-conductor VVF cables (vinyl-insulated vi-
nyl sheath cables) are used.

Maximum extension
(reference)

Conductor
diameter

100 m

260 m

410 m

500 m

1.0

mm 1.6

mm 2.0

mm 2.6

mm

and more and more and more and more

Remove the terminal board
cover by flipping it up while
pushing its top to the left.

RX+ C

RX– D

A TX+

B TX–

Terminal board

Lug plates

DC 12 V or AC 24 V
power cable

To DC 12 V or AC
24 V power supply

Control signal cable

To Remote Control
Unit (RM-P2580)

To Remote Control Unit
(RM-P2580)

Video
signal cable

• Do not allow input from both a DC 12 V

and AC 24 V power supply at the same
time.

• When using a DC 12 V power supply,

ensure that the polarities of the cable are
correct.

• The AC 24 V power supply should con-

form to the following:
U-type: Class 2 only
E-type: Isolated power supply only

• Turn OFF the power supply to all components before making connections.

CAUTION:

• If thin cables are used (i.e. with a high

resistance), a significant voltage drop
will occur when the unit is at its
maximum power consumption. Either
use a thick cable to restrict the voltage
drop at the camera side to below 10%,
or place the power supply near to the
camera. If voltage drop occurs during
operation, the performance will be
unstable.

• Attach the cable conductors so that they

do not come into contact with the drop
prevention wires.

Advertising