How to use external control, About the external control – JVC GM-F520S User Manual

Page 20

Advertising
background image

20

LAN

<IR OUT system>
Control signals from the remote control of external equipment are sent out to the equipment through the RS-
485 OUT terminal. Consult your dealer for details.
• You cannot use the IR OUT system and the serial communication via the RS-485 terminal at the same time.

About the external control

This monitor has the following external control terminals:
RS-232C terminal: Controls the monitor by external control equipment (a personal computer or a dedicated

controller) (see “Using the serial communication” on page 21).

RS-485 terminals: The following external control systems are available.

(1) Serial communication: Controls the monitor by external control equipment (a personal computer or a

dedicated controller) (see page 21).

(2) IR OUT system: Controls other equipment through the monitor by using the remote control supplied

with the equipment.

(3) MAKE (make contact system): Controls the function by short-circuiting the corresponding pin terminal

to the GND pin terminal, or disconnecting (opening) it (see page 22).

(4) TRIG. (trigger system): Controls the function by inputting the pulse signal instantaneously to the

corresponding pin terminal (see page 22).

LAN terminal (10BASE-T): Controls the monitor from a PC in the network through the web browser (see

“Using the LAN system” on page 23).

Set the following items in “REMOTE SYSTEM” according to the external control terminal and control system
you use (see page 15).

Control system

“REMOTE IN SEL.”
setting

“CNT. RJ45 OUT”
setting

“CNT. RJ45 IN” setting

Serial
communication

RS-485

RJ-45*

1

RS485

RS485

RS-232C

D-sub9*

1

RS485

RS485

IR OUT system

Any

IR OUT

Any

MAKE system

RJ-45

RS485

MAKE

TRIG. system

RJ-45

RS485

TRIG.

LAN system*

2

LAN

Any

Any

*

1

For the monitor connected to the external control equipment, set “REMOTE IN SEL.” according to the actual

connection. Set other monitors to “RJ-45.”

*

2

Set “NETWORK SETTING” in the set-up menu (see pages 16 and 23).

NOTE

• The functions controlled by an external device through the MAKE connection cannot be controlled on the

main unit or the remote control.

• While the Control Lock (see page 16) is in use, you can use external control.

<Serial communication>
Several monitors can be controlled by connecting their RS-485 IN and OUT terminals. See also page 21.
Do not use the AC OUT terminal on the monitor for power supply to another monitor.

How to Use External Control

RS-485 IN
or RS-232C

RS-485
OUT

RS-485
IN

RS-485
OUT

RS-485
IN

RS-485
OUT

External control
equipment

Karaoke
component, etc.

Remote control

RS-485
OUT

<MAKE/TRIG. system>
You can control the monitor by external control equipment*

3

. See also page 22.

*

3

External control equipment is not commercially available. Consult your dealer if you need a dedicated

controller.

<LAN system>
You can control the monitor from PC in your Local Area Network (LAN) through the web browser.

PC

PC

PC

Hub

Hub

Monitor

GM-F520S_EN.indd 20

GM-F520S_EN.indd 20

09.2.16 5:05:13 PM

09.2.16 5:05:13 PM