10

REPLACEMENT OF MEMORY ICs

1. MEMORY ICs

This model uses memory ICs. This memory IC data are for proper operation of the video and deflection circuits.
When replacing memory ICs, be sure to us e ICs written with the initial values of data.

2. PROCEDURE FOR REPLACING MEMORY ICs

(1) Power off

Switch the power off and disconnect the power plug from the wall outlet.

(2) Replace ICs

Be sure to use memory ICs written with the initial data values.

(3) Power on

Connect the power plug into the wall outlet and switch the power on.

(4) Check and set SYSTEM CONSTANT SET

It must not adjust without adjustment signals.

1) Press the DISPLAY key and the PICTURE MODE key of the REMOTE

CONTROL UNIT simultaneously.

2) The SERVICE MENU screen of Fig. 1 will be displayed.

3) While the SERVICE MENU is displayed, again press the DISPLAY key and

PICTURE MODE key simultaneously, and the SYSTEM CONSTANT SET
screen of Fig. 2 will be displayed.

4) Check the s etting values of the SYSTEM CONSTANT SET of T able 1 If the

value is different, select the setting item with the MENU ▼/▲key, and set
the correct value with the MENU - / + k ey.

5) Press the DISPLAY key twice, and return to the normal screen.

(5) Receive channel of setting

Refer to the OPERATING INST RUCTIONS and set the receive channels
(channels preset) as described

(6) User Setting

Check the us er s etting value of Table 2, and if setting value is different, set
the correct value.
For setting, refer to the OPERATING INSTRUCTIONS.

(7) Setting of SERVICE MENU

Verify the setting items of the SERVICE MENU, and reset where necessary.
For setting, refer to the SERVICE ADJUSTMENTS.

NOTE

Although the k ey position of the RM-C90 remote control unit is different from
that of the RM-C364GY & RM-C354 remote control unit, the func tions of both
units are the same So pleas e us e the attached diagram for the RM-C90
remote control unit for the RM-C364GY & RM-C364.
By the way, MENU -/+ Key functions in the same manner as for / key.

SERVICE MENU

1.IF 2.V/C

3.DEF 4.VSM PRESET

5.PRESET
6.SETUP TOUR OFF

1-6 SELECT DISP : EXIT
******

******

******

****** *****

*****

*****

***** **

**

**

**

.

***

***

***

***

*** ** **

*** ** **

*** ** **

*** ** ** ** ***

** ***

** ***

** ***

Fig.1

Fig.2

DISPLAY key

MENU

/ key

MENU

▼/▲ key

PICTURE

MODE key

(RM-C90)

NUMBERS

key

KEY ASSIGNMENT OF REMOTE CONTROL UNIT

SYSTEM CONSTANT-

COLOUR

:

BILINGUAL

: NO

TUNER

: MU

ECO SENSOR

: YES

LANGUAGE

:

SYSTEM CONSTANT SET 1

***

***

: SELECT

- / + : OPERATE

DISP : EXIT

/

SYSTEM CONSTANT-

B/B SOUND

: OFF

LOCK

: 180

COLOUR AUTO

:

QSS

: MINT

ALC

: NO

TEXT RATE

: 20

SYSTEM CONSTANT SET 2

***

: SEL - / + : OPE DISP : EXIT

/

SYSTEM CONSTANT-

AMP TUNER

: NO

VNR

: YES

TEXT TABLE :

VOLUM PWM

: POS

SYSTEM CONSTANT SET 3

***

: SEL - / + : OPE

DISP : EXIT

/