25

Item

Measuring

instrument

Test point

Ad justment part

Description

6. TINT

[Method of adjustment without measuring instrument]

NTSC 3.58 TINT

1. Input a NTSC 3.58 full field colour bar signal (75% white).
2. Enter the SERVICE MENU.
3. Select 2. V/C from SERVICE MENU.
4. Select 6. TINT with the MENU ▼/▲ key.
5. Set the initial s etting value of NTSC 3.58 with the MENU - / +

key.

6. If you cannot get the best tint with the initial s etting value, make

fine adjustment until you get the best tint.

Ad justment
of TINT

Signal
generator

Remote
control unit

NTSC 4.43 TINT

When NTSC 3.58 is set, NTSC 4.43 will be automatically set at the
respective values .

6. TINT

[Method of adjustment using measuring instrument]

NTSC 3.58 TINT

1. Input a NTSC 3.58 full field colour bar signal (75% white).
2. Enter the SERVICE MENU.
3. Select 2. V/C from SERVICE MENU.
4. Select 6. TINT with the MENU ▼/▲ key.
5. Set the initial s etting value of NTSC 3.58 with the MENU - / +

key.

6. Connect the osc illosc ope between TP-47G/R and TP-E. (#).
7. Adjust NTSC 3.58 TINT to bring the value of

(B)

in the

illustration +9V(W- Cy). (Voltage value between (W) and (Cy))

Ad justment
of TINT

Signal
generator

Oscillo-
scope

Remote
control unit

TP-47G/R
TP-E (
#

#

#

#

)

[CRT
SOCKET
PWB]

NTSC 4.43 TINT

When NTSC 3.58 is set, NTSC 4.43 will be automatically set at the
respective values .

W

Y

Cy

G

Mg

R

B

(B)