Warning, Important, Choice of electrical connections – John Lewis JLBIDOS906 User Manual

Page 6: Do not lift the appliance by the handles

Advertising
background image

6

The appliance socket switch should be outside the

cabinet but within 2m of the appliance to make it

accessible to switch off the appliance in case of an

emergency.

To protect the hands, wear gloves when lifting the

oven into its housing.

Warning

Do not lift the appliance by the handles.

Important

House circuit

Earth leakage and continuity tests must be carried out before

the appliance is connected to the mains supply and re-checked

after fitting.

Connection

via

Min. size

Cable/flex

Cable/flex

type

Fuse

Cooker

Control

Circuit

6mm

2

PVC/PVC

twin and

earth

35 A (min)

Choice of electrical
connections

There are three possible ways to connect your

appliance. In each case the appliance should be

operated using at least 6mm

2

twin core and earth PVC

insulated. Please choose from the most appropriate

after reading the different methods: -

a)

By connecting the appliance to a cooker point (having a

double pole isolating switch with at least 3mm contact

separation in all poles and neutral) and protected with

a fuse or miniature circuit breaker at your mains fuse

box.

Important

Subject to Regional Electricity Companies regulations if you

wish to connect the oven and hob to the power supply you

may use one of the following two methods: -

b)

By connecting the appliance together with a hob

directly to a cooker point(s). Having a double pole

isolating switch with at least 3mm contact separation in

all poles and neutral.

c)

If you wish to connect an oven and a hob to a cooker

point you can by connecting the oven and hob

separately to the cooker point. Oven and hob units

should be separately connected to a cooker point.

Important

It is good practice to:

Fit an Earth Leakage Circuit Breaker to your house

wiring.

Wire your appliance to the latest IEE regulations.

To remove the mains terminal
cover

From the rear of the appliance, remove mains input

terminal cover to gain access to terminal block.

First remove retaining screw with a pozidrive

screwdriver.

Prise cover loose using screwdriver in position (1) then

lever off with screwdriver in position (2) at either side.

Lift cover and remove screw from cable clamp.

Advertising